TWINDOSE <strong>35</strong> – System for dishwashers<br />

2.3 CIRCUIT DIAGRAM<br />

1 2 3 4 5 6 7 8 9 10 11 12 13<br />

AC<br />

OUT<br />

DET<br />

AC<br />

OUT<br />

RINSE<br />

AC<br />

OUT<br />

SANI<br />

1 2 3 4 5<br />

AC MAINS AC MAINS<br />

DETERGENT RINSE<br />

CHARGE<br />

SIGNAL<br />

6 7 8<br />

RINSE<br />

9 10<br />

WASH<br />

SIGNAL SIGNAL<br />

14 15 16<br />

11 12<br />

ALARM<br />

OUT<br />

13 14 15 16 17 18 19 20 21 22 23 24<br />

DETER RINSE SANIT TEMP COND PROBE<br />

INPUT SIGNAL PROBE<br />

LOW-HIGH<br />

HIGH-LOW<br />

LOW-HIGH<br />

HIGH-LOW<br />

20 21 22<br />

LOW-HIGH<br />

HIGH-LOW<br />

17 18 19<br />

DC OUT DET<br />

DC OUT RINSE<br />

DC OUT SANI<br />

23<br />

+7.5V<br />

-7.5V<br />

+5V<br />

DOOR<br />

PROBELESS<br />

COND PROBE<br />

RINSE SPEED<br />

SANI W/DET<br />

RINSE LIM OFF<br />

LEV STOP OFF<br />

CONVEYOR<br />

PROBE<br />

IND PROBE<br />

RINSE TIME<br />

SANI W/RINSE<br />

RINSE LIM ON<br />

LEV STOP ON<br />

POT 1<br />

RINSE<br />

SPEED<br />

TIME<br />

POT 2<br />

SANIT<br />

SPEDD<br />

HIGH<br />

AUDIO<br />

LOW<br />

DETER<br />

RECHARGE OFA<br />

SETPOINT TIME<br />

POT 3<br />

POT 4<br />

24<br />

POT 5<br />

DETER<br />

INIT CHRG<br />

25<br />

26 27 28 29 30<br />

Fig. 3<br />

1 AC MAINS DETERGENT: entry fuse 16 Sanitizer AC motor output<br />

2 AC MAINS DETERGENT: detergent signal input 17 Detergent DC motor output<br />

3 AC MAINS RINSE: rinse aid signal input 18 Rinse aid DC motor output<br />

4 AC MAINS RINSE: entry fuse 19 Sanitizer DC motor output<br />

5 CHARGE SIGNAL: charge signal input 20<br />

Voltage range selection jumper for charge signal<br />

input<br />

6 RINSE SIGNAL: rinse signal input 21<br />

Voltage range selection jumper for rinse signal<br />

input<br />

7 WASH SIGNAL: wash signal input 22<br />

Voltage range selection jumper for wash signal<br />

input<br />

8 Alarm relay output 23<br />

Input from optional module for 24 Vac power<br />

supply.<br />

9 Detergent level signal input 24 Buzzer volume selector<br />

10 Rinse aid level signal input 25 DIP-switch for programming the system<br />

11 Sanitizer level signal input 26<br />

POT1: Rinse pump speed / rinse pump dosing<br />

time<br />

12 Temperature probe connector 27 POT2: Sanitizer pump speed<br />

13 Conductometric sensor connector 28<br />

POT3: Detergent pump reset time / Conductivity<br />

set point setting<br />

14 Detergent AC motor output 29 POT4: OFA time setting<br />

15 Rinse aid AC motor output 30 POT5: Initial detergent pump charge time<br />

TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 8