12.01.2015 Views

Seko Twindose 35 Series Inst.. - UK

Seko Twindose 35 Series Inst.. - UK

Seko Twindose 35 Series Inst.. - UK

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TWINDOSE <strong>35</strong> – System for dishwashers<br />

5.1.3 Dosing the detergent in timer mode<br />

To select the timer mode for the detergent pump, DIP-switch 2 must be switched to the OFF (PROBELESS)<br />

position. The pump will run at top speed for the time set using potentiometer POT3.<br />

CAL. OFF<br />

CAL. ON<br />

In this configuration, POT4 regulates the detergent dosing time during the rinsing phase, while detergent dosing<br />

during the 1 st charging phase is controlled by potentiometer POT5 that sets the dosing time when a signal is<br />

received on the CHARGE SIGNAL terminal.<br />

5.2 RINSE AID DOSING<br />

When the TWINDOSE <strong>35</strong> unit receives a signal on the RINSE SIGNAL terminal, the rinse aid pump doses in terms<br />

of a volumetric (speed) setting or timer setting, depending on the selection made using DIP-switch 4 (RINSE<br />

SPEED / RINSE TIME).<br />

5.2.1 Dosing the rinse aid in by setting the volume (RINSE SPEED)<br />

CAL. OFF<br />

CAL. ON<br />

If the volumetric (RINSE SPEED) dosing mode is selected:<br />

• Set DIP-switch 4 (RINSE SPEED / RINSE TIME) to RINSE SPEED (OFF position).<br />

• Set the rinse aid pump flow rate to between 0% and 100% of the top speed (using potentiometer POT1).<br />

To change the pump speed, simply turn potentiometer POT1 clockwise to increase speed and anticlockwise to<br />

reduce speed.<br />

5.2.2 Dosing rinse aid by setting the timer (RINSE TIME)<br />

CAL. OFF<br />

CAL. ON<br />

If the timer dosing mode is selected:<br />

• Set DIP-switch 4 (RINSE SPEED / RINSE TIME) to RINSE TIME (ON position).<br />

• Set the dosing time for the rinse aid pump to between 1 and 255 seconds (using potentiometer POT1).<br />

To change the pump dosing time, simply turn potentiometer POT1 clockwise to increase and anticlockwise to<br />

reduce.<br />

TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 22