TWINDOSE <strong>35</strong> – System for dishwashers<br />
5 SETTING AND OPERATION<br />
5.1 DETERGENT DOSING<br />
5.1.1 Dosing the detergent in conductometric mode (PROBE)<br />
To set the machine to conductometric sensor (PROBE) detergent dosing mode, switch the DIP-switch 2 to the<br />
“ON” (PROBE) position. The pump doses at top speed until the set point is reached.<br />
CAL. OFF<br />
CAL. ON<br />
When TWINDOSE <strong>35</strong> receives a signal from the dishwasher’s washing pump on its IN WASH terminal, the<br />
conductometric sensor detects the concentration in the tank. When the concentration drops below the set point,<br />
set using potentiometer POT3, the control circuit automatically activates the detergent pump and stops when the<br />
conductivity in the tank rises more than 10% higher than the set point.<br />
The detergent pump’s speed depends on how much the concentration in the tank differs from the set point:<br />
• When the concentration in the tank is below 80% of the set point, the pump doses at top speed.<br />
• When the concentration in the tank is between 80% and 90% of the set point, the pump doses at 50% of its<br />
top speed.<br />
• When the concentration in the tank is above 90% of the set point, the pump doses at 25% of its top speed.<br />
If TWINDOSE <strong>35</strong> does not receive a signal on its IN WASH terminal, the control circuit will not activate detergent<br />
dosage, even if the concentration of detergent in the tank is below the set point.<br />
If the correct concentration of detergent is not reached within the two OFA time intervals set, the “OFA2” alarm<br />
is activated automatically and detergent dosage stops.<br />
In this alarm state, the LED configuration is as follows.<br />
• DET LED: flashing<br />
• ALARM LED: lit permanently<br />
• The buzzer sounds continuously.<br />
• The alarm relay output is activated.<br />
To reset the alarm status, eliminate the cause and restart the system.<br />
TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 20