TWINDOSE <strong>35</strong> – System for dishwashers<br />

3.2.4 Potentiometer POT4 (OFA TIME)<br />

1s.<br />

Disabled<br />

255 sec<br />

The OFA alarm is activated when the detergent concentration in the tank does not reach the set point within the<br />

time set using the POT4 (OFA TIME) potentiometer.<br />

As soon as detergent dosage begins, TWINDOSE <strong>35</strong> doses in conductometric mode (with probe) for the OFA time<br />

set using the POT4 (OFA TIME) potentiometer. Once this period of time has expired, if the detergent pump is still<br />

running the system goes into an OFA1 alarm phase:<br />

• The alarm LED flashes.<br />

• The buzzer sounds intermittently.<br />

• During this initial phase the pumps do not cut out.<br />

This alarm status ends if the detergent pump stops before the second OFA time (OFA2) has expired.<br />

If the detergent pump continues dosing for a further OFA interval, the device enters a second OFA phase, known<br />

as OFA2.<br />

During this alarm phase (OFA2):<br />

• The buzzer sounds continuously.<br />

• The LED stays lit permanently.<br />

• The detergent pump stops.<br />

PLEASE NOTE: The detergent pump will not start up again. To reset proper functioning, eliminate the<br />

cause of the alarm and then switch the system off and on again.<br />

The OFA time can be set using the POT4 (OFA TIME) trimmer, for a period of between 1 second and 255<br />

seconds.<br />

To disable the OFA alarm, turn the POT4 (OFA TIME) trimmer all the way to the left.<br />

3.2.5 Potentiometer POT5 (DETER INIT CHARGE)<br />

1sec<br />

255 sec<br />

This potentiometer manages the dosing time for the detergent pump during the first charging phase, and it is<br />

activated when TWINDOSE <strong>35</strong> receives a signal on the CHARGE SIGNAL terminal.<br />

The time setting can vary between 1 and 255 seconds.<br />

TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 18