TWINDOSE <strong>35</strong> – System for dishwashers<br />

7.2.4 Detergent level alarm without pumps cutting out<br />

The green LED A (power) stays on, this LED shows that the TWINDOSE <strong>35</strong> is switched on.<br />

• The buzzer sounds intermittently<br />

• The relay output is enabled<br />

• The detergent pump is ready to dose<br />

• The red LED B (alarm) stays on<br />

• The green LED C (detergent) flashes<br />

7.2.5 Rinse aid level alarm without pumps cutting out<br />

The green LED A (power) stays on, this LED shows that the TWINDOSE <strong>35</strong> is switched on.<br />

• The buzzer sounds intermittently<br />

• The relay output is turned on<br />

• The rinse aid pump is ready to dose<br />

• The red LED B (alarm) stays on<br />

• The green LED D (rinse aid) flashes<br />

7.2.6 *Sanitizer level alarm without pumps cutting out<br />

The green LED A (power) stays on, this LED shows that the TWINDOSE <strong>35</strong> is switched on.<br />

• The buzzer sounds intermittently<br />

• The relay output is enabled<br />

• The sanitizer pump* is ready to dose<br />

• The red LED B (alarm) stays on<br />

• The green LED E* (sanitizer) flashes<br />

7.2.7 Detergent level alarm with pumps cutting out**<br />

This function can be excluded by selecting LEV STOP OFF on DIP-switch 8<br />

The green LED A (power) stays on, this LED shows that the TWINDOSE <strong>35</strong> is switched on.<br />

• The buzzer sounds continuously<br />

• The relay output is turned on<br />

• The red LED B (alarm) stays on<br />

• The green LED C (detergent) flashes<br />

• The pumps cut out<br />

7.2.8 Rinse aid level alarm with pumps cutting out**<br />

This function can be excluded by selecting LEV STOP OFF on DIP-switch 8<br />

The green LED A (power) stays on, this LED shows that the TWINDOSE <strong>35</strong> is switched on.<br />

• The buzzer sounds continuously<br />

• The relay output is turned on<br />

• The red LED B (alarm) stays on<br />

• The green LED D (rinse aid) flashes<br />

• The pumps cut out<br />

7.2.9 Sanitizer level alarm with pumps cutting out**<br />

This function can be excluded by selecting LEV STOP OFF on DIP-switch 8<br />

The green LED A (power) stays on, this LED shows that the TWINDOSE <strong>35</strong> is switched on.<br />

• The buzzer sounds continuously<br />

• The relay output is turned on<br />

• The red LED B (alarm) stays on<br />

• The green LED D (sanitizer) flashes<br />

• The pumps cut out<br />

*Only in the 3 pump systems<br />

TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 38