TWINDOSE <strong>35</strong> – System for dishwashers<br />
<br />
WASH SIGNAL<br />
In this configuration, the WASH SIGNAL is not managed, since in single-tank probeless (DOOR-PROBELESS)<br />
mode, the detergent concentration control takes place without a conductometric sensor, using the timed dosing<br />
mode (PROBELESS).<br />
6.4 CONVEYOR DISHWASHING MACHINES (CONVEYOR) – PROBE DOSING<br />
This mode is set by setting the DIP-switches in this configuration:<br />
CAL. OFF<br />
CAL. ON<br />
<br />
CHARGE SIGNAL<br />
DETERGENT PUMP<br />
When the signal from the solenoid valve that controls the 1 st charge signal is activated, the detergent pump doses<br />
for a time (between 0 and 255 seconds) set using potentiometer POT5 (DETER INIT CHRG).<br />
DETER<br />
INIT CHRG<br />
0 sec 255 sec<br />
The dosing time set will be completed even if the charge signal is de-activated during dosing.<br />
RINSE AID PUMP<br />
The rinse aid pump is not activated.<br />
SANITIZER PUMP (OPTIONAL)<br />
The sanitizer pump (optional) is activated simultaneously with the detergent pump only if previously set by moving<br />
DIP-switch 6 to the “OFF” position (SANI W/DET).<br />
CAL. OFF<br />
CAL. ON<br />
If DIP-switch 6 is set in the “ON” position (SANI W/RINSE), the sanitizer pump will not be activated.<br />
TWINDOSE <strong>35</strong> code 0000136655 rev. 1.0 30