Mouse Latency Allowance<br />

This option is used during calibration to account for latency delays (caused as signals pass<br />

through a device) introduced by some KVM switches. During calibration, the Vista Remote 2<br />

waits for 40ms after each mouse movement before sampling the next. If a KVM device adds a<br />

significant delay to the flow of data, the calibration process can be lengthened or may fail<br />

entirely. The value entered here is added to (or subtracted from) the default 40ms sampling<br />

time.<br />

Note: You can enter negative values (down to -40) in order to speed up the<br />

calibration process. Use this option with caution as it can adversely affect<br />

the calibration process.<br />

Mouse rate<br />

Defines the rate at which mouse movement data are transmitted to the system. The default<br />

option is 20ms, which equates to 50 mouse events per second. This default rate can prove too<br />

fast when passed through certain connected KVM switches. In such cases, data are discarded<br />

causing the local and remote mouse pointers to drift apart. If this effect is encountered,<br />

increase the mouse rate to around 30ms (data are then sent at a slower rate of 33 times per<br />

second).<br />

Background refresh rate<br />

Use the arrow keys to alter the refresh rate for screen images via remote links. This allows you<br />

to tailor the screen refresh to suit the network connection speeds. The options are: Slow,<br />

Medium, Fast or Disabled. When the disabled option is selected, the remote users will need to<br />

manually refresh the screen.<br />

Note: When a low connection speed is detected, the background refresh is automatically<br />

disabled, regardless of the settings of this option.<br />

Single Mouse Mode Mouse Switch<br />

This option allows you to select the mouse button combination that can be used to exit from<br />

single mouse mode (when active). Options are: Disabled, Middle+Right Button, Middle+Left<br />

Button.<br />

Behavior for admin connections when limit reached<br />

Use the arrow keys to modify the action taken when the number of admin connections is<br />

reached. The options are:<br />

• Replace oldest connection<br />

• Replace newest connection<br />

• Don’t replace<br />

Use VESA GTF<br />

When ticked, the VESA Generalized Timing Formula will be used to help determine the correct<br />

input video resolution and timing details. See Appendix G for a list of all supported video<br />

modes.<br />

Upgrade Firmware<br />

The Upgrade Firmware tab allows you to easily update the firmware when changes and<br />

enhancements have been made to the Vista Remote 2.<br />

Reset Unit<br />

The reset unit tab, when selected, will reset the Vista Remote 2 unit to factory defaults. All user<br />

settings that have been entered will be replaced with the factory default settings.<br />