19.01.2015 Views

condair FF2

condair FF2

condair FF2

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

19<br />

4.2 Accessories and options<br />

Accessories<br />

Accessory<br />

High-pressure hose for<br />

high-pressure piping<br />

Anti-chafe spiral hose<br />

RJ45 bus cable<br />

Description<br />

High-pressure hoses for establishing the high-pressure<br />

piping between the high-pressure connectors of the<br />

pump.<br />

Hoses of 2 m, 5 m or 10 m length available (from stock)<br />

The anti-chafe spiral hose protects the high-pressure<br />

hoses in locations where they are subject to get in touch<br />

with each other or with other system components.<br />

Length: 3 m<br />

The bus cable connects the control units of a masterslave<br />

configuration.<br />

Length: 10 m or 20 m<br />

Options<br />

Option<br />

Floor stand for pump station<br />

Droplet separator<br />

Remote operating and fault<br />

indication<br />

Conductivity monitoring<br />

Flushing valve Y6<br />

e-LINKS <strong>FF2</strong><br />

Floor stand for pump station<br />

Floor stand made of corrosion resistant steel, for mounting<br />

the pump station at a convenient height for easy operation.<br />

Droplet separator in frame construction made of corrosion<br />

resistant steel equipped with collector meshes with<br />

a special biocide coating.<br />

With unfavourable flow conditions and/or high air speed<br />

in the duct additionally a deflection sheet is provided for<br />

the optimization of the incident air flow of the first droplet<br />

separator.<br />

Print with relay contacts for the remote indication of the<br />

following operating conditions: Unit on, Humidification,<br />

Error and Maintenance.<br />

The conductivity monitoring, consisting of the conductivity<br />

sensor and the conductivity print, monitors the<br />

electrical conductivity of the water and outputs an error<br />

message if the lower limit value is exceeded.<br />

Flushing valve for the automatic flushing of the high<br />

pressure piping during operation. The flushing valve is<br />

installed directly to the step valve block.<br />

Gateway to connect the Condair <strong>FF2</strong> to a building management<br />

system. Two versions are available:<br />

BACnet/IP or LonWorks