Switched-mode power supply units,<br />

power supply units<br />

4/156<br />

Technical Data<br />

Switched-mode power supply units<br />

SN3<br />

SN3-000-MMEU8<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

General<br />

Standards IEC 61204<br />

73/23/EWG<br />

89/336/EWG<br />

EN 50178, EN 60950, UL 60950, UL 508<br />

Duty factor % 100<br />

Dimensions (W x H x D) mm 56,25 x 54 x 24 (when mounted)<br />

Weight kg 0.065<br />

Terminal capacities<br />

Flexible with ferrule mm 2 0.2…2.5 (22…14 AWG)<br />

Flexible without ferrule mm 2 0.2…2.5 (22…14 AWG)<br />

Massive mm 2 0.2…4 (22…14 AWG)<br />

Degree of protection<br />

Enclosures IP20<br />

Terminals IP20<br />

Protection class 2<br />

Mounting Plugged into power supply unit<br />

Fixing Snap fastener, tool-less<br />

Vibrations (IEC/EN 60068-2-6) 1…57 Hz, amplitude g0.075 mm, 57…100 Hz, 5 g<br />

Mechanical shock resistance (IEC 60068-2-27) 5 g all directions<br />

Environmental compatibility<br />

Ambient temperature<br />

Operation °C –25…+70<br />

Storage °C –40…+85<br />

Climatic proofing 93% at +40°C according to IEC 60068-2-3, no condensation<br />

Climatic class (IEC) 3K3 according to EN 60721<br />

Insulation voltage<br />

Rated insulation voltage Ui V AC 250 according to IEC 60974-1, EN 50178, VDE 0160<br />

Power supply/measuring circuit/relay outputs Safe isolation according to EN 50178, EN 60950<br />

Rated impulse withstand voltage between all<br />

insulated circuits<br />

Uimp kV 4 according to IEC 664, VDE 0110<br />

Test voltage between all circuits kV 2.5 AC (routine test)<br />

Overvoltage category/pollution degree according to EN 60950, Class 2<br />

Input circuit<br />

Rated input voltage V 110…240 AC / 100…350 DC<br />

(supplied from the input circuit of the power supply)<br />

Input voltage range V 70…264 AC<br />

Input voltage range V 80…350 DC<br />

Power consumption VA 2.5<br />

Power consumption W 1.5<br />

REMOTE-OFF input<br />

Switch off<br />

potential-free<br />

R F 1 kO<br />

Switching on R f 10 kO<br />

Input current mA typically 1 (200 mA for 200 ms)<br />

Cable length m 25<br />

Measuring circuits<br />

INPUT<br />

Monitoring function Undervoltage monitoring<br />

Threshold values 85 V AC/90 V DC<br />

Accuracy/tolerance % -5 % for AC and DC<br />

Hysteresis with respect to the threshold value typically -8 % for AC and -30 % for DC<br />

Measuring cycle max. ms Normally F 50<br />

OUTPUT<br />

Monitoring function Undervoltage monitoring<br />

Threshold values 20 V DC<br />

Accuracy/tolerance % 1<br />

Hysteresis with respect to the threshold value % Normally 5<br />

Measuring cycle max. ms Normally F 10<br />

http://catalog.moeller.net<br />

For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616