20.03.2015 Views

HBC-4301 Operators Manual - Novatech Controls

HBC-4301 Operators Manual - Novatech Controls

HBC-4301 Operators Manual - Novatech Controls

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3. SPECIFICATIONS<br />

3.1 Hardware Specifications<br />

NATO Stock Number is 6685-66-145-0064<br />

The central or main component of the <strong>HBC</strong>-4300 series is the <strong>HBC</strong>-<strong>4301</strong> control case.<br />

The case contains the notebook computer for transportation, and also: –<br />

The main microcomputer<br />

Thermocouple reading circuitry<br />

Heater control<br />

Backup keypad / display<br />

Automatic vacuum control pumps and circuitry<br />

Number of T/C inputs: 16 (expandable to 32)<br />

Thermocouple type:<br />

Temperature range:<br />

Accuracy:<br />

Type K or J<br />

Up to 300C (600F)<br />

+/- 1C<br />

Number of heater zones inputs: 3 (expandable to 6 zones)<br />

Type of controlled output:<br />

Heater current (max.):<br />

Heater power:<br />

Phase angle and burst fired SCRs to operate infra-red<br />

heater lamps or mats<br />

10 Amps<br />

7.2kW total at 240vac supply (2.4kW per zone)<br />

3.3kW total at 110vac supply (1.1kW per zone)<br />

Power supply safety protection: Earth leakage circuit protection on each heater<br />

Vacuum sources:<br />

Vacuum control (Pump #1):<br />

Vacuum control (Pump #2):<br />

Air supply:<br />

Mains voltage supply:<br />

Power:<br />

Safety switch:<br />

2 Air operated ejectors, down to -85 kPa<br />

<strong>Manual</strong> on / off<br />

Automatic, programmable or manual setting<br />

150 to 800 kPa (Normal operation 500kPa)<br />

200 l/m (both pumps running at 100%)<br />

Single phase or 3 phase<br />

85 to 265VAC 50/60 Hz (phase to neutral)<br />

10Watts for controller plus heater power<br />

Earth leakage detector on each zone (30mA)<br />

Environmental Rating: Operating Temperature -25°C to 55°C<br />

Relative Humidity 5% to 95% (non-condensing)<br />

Page 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!