9.3 Repair map<br />
This is the most useful screen to monitor the performance of a heat cycle at a glance. The<br />
temperature of all the thermocouples can be seen superimposed onto a map of the repair.<br />
The heaters can be set to an approximate shape and thermocouples placed in position as<br />
selected by the operator. Once the temperature profile has been started, the temperature tags<br />
will be attached to each thermocouple.<br />
If a thermocouple is not within the temperature alarm thresholds (default settings are 2.5C or<br />
5C, set in the Thermocouple and Zone Parameters screen) of the set point temperature the<br />
background of the temperature tag will be set to light-blue / pink or dark-blue / red. Using<br />
this method a cold or hot area of the repair will stand out at a glance.<br />
Fig. 16 Repair Map Screen<br />
In addition to colour coding of the actual temperatures, the control thermocouple circle (if the<br />
highest thermocouple temperature has been selected for control) is set to red and the<br />
acceptance thermocouple is set to blue.<br />
When the repair is finished, the repair map is also saved. When a repair temperature profile is<br />
retrieved for later examination the position of the heaters and thermocouples will also be<br />
available.<br />