9.3 Repair map<br />

This is the most useful screen to monitor the performance of a heat cycle at a glance. The<br />

temperature of all the thermocouples can be seen superimposed onto a map of the repair.<br />

The heaters can be set to an approximate shape and thermocouples placed in position as<br />

selected by the operator. Once the temperature profile has been started, the temperature tags<br />

will be attached to each thermocouple.<br />

If a thermocouple is not within the temperature alarm thresholds (default settings are 2.5C or<br />

5C, set in the Thermocouple and Zone Parameters screen) of the set point temperature the<br />

background of the temperature tag will be set to light-blue / pink or dark-blue / red. Using<br />

this method a cold or hot area of the repair will stand out at a glance.<br />

Fig. 16 Repair Map Screen<br />

In addition to colour coding of the actual temperatures, the control thermocouple circle (if the<br />

highest thermocouple temperature has been selected for control) is set to red and the<br />

acceptance thermocouple is set to blue.<br />

When the repair is finished, the repair map is also saved. When a repair temperature profile is<br />

retrieved for later examination the position of the heaters and thermocouples will also be<br />

available.<br />