Fig. 9 Start Cycle Table Screen warning message<br />
If the button Start Bonding Cycle does not appear in the bottom right hand corner of the<br />
table screen the reason will be identified in the button position. Messages include:<br />
Message in the button<br />
Primary Not Connected<br />
Secondary Not Connected<br />
Zone x not ready<br />
No enabled zones<br />
Task active<br />
Local mode<br />
Reason and the solution<br />
The PC is not communicating with the primary <strong>HBC</strong>-<strong>4301</strong><br />
control case.<br />
Check that the <strong>HBC</strong>-<strong>4301</strong> has been set to Primary in setup<br />
function #1, and the communications cable at both ends.<br />
The PC is not communicating with the secondary <strong>HBC</strong>-<strong>4301</strong><br />
control case.<br />
Check that the <strong>HBC</strong>-<strong>4301</strong> has been set to Secondary in setup<br />
function #1, and the communications cable at both ends.<br />
One of the nominated zones does not have any thermocouples<br />
associated with the zone.<br />
Check the Repair Map layout, and that the thermocouples are<br />
operating correctly (not o/c).<br />
No zones have been associated with the task.<br />
Check the Repair Map layout.<br />
The task is running already.<br />
Use the Halt Heat Cycle function from the Main Menu to stop<br />
the heat cycle.<br />
The control case is set to Local mode.<br />
Use the Setup button and the Function buttons on the <strong>HBC</strong>-<br />
<strong>4301</strong> control case to find setup function #1. Set the option to<br />
Primary or Secondary.<br />
Fig. 10 Start cycle screen data entry<br />
After the above two fields have been entered, an optional adhesive can be entered.<br />
Page 35