10. CHANGING A RUNNING TEMPERATURE PROFILE<br />

The actual heat cycle currently being run may be altered while the run is still in progress<br />

without stopping the cycle. Select Change Zone in Progress (F4) from the main menu. An<br />

edit box will appear for selection of heater zone of control. Select the zone number between 1<br />

& 3 (or optionally up to 6) that you wish to modify, and press or click on OK.<br />

Fig. 17 Change zone in progress screen<br />

The graph on the left of the screen will show you the shape of the temperature profile being<br />

used. The table of temperatures and times on the right define the shape of the profile. The<br />

table may be edited, and the result can be seen immediately on the graph.<br />

Logically only the part of the profile that has not yet been reached can be changed.<br />

The following table shows what can be changed after a job has been started:<br />

Ramp rate Soak temperature Soak time<br />

When ramping Not changeable Changeable Changeable<br />

When soaking Not changeable Not changeable Not changeable<br />

A stage that has not yet Changeable Changeable Changeable<br />

started<br />

A stage that has been<br />

completed<br />

Not changeable Not changeable Not changeable<br />

For example, the target temperature of a stage may be changed if the set point is still<br />

ramping up to the soak temperature. The ramp rate, target temperature and soak time can be<br />

changed of a stage that has not been started.<br />

Page 47