The Host Validation Record Extract Options screen specifies the method to locate<br />

the validate field within the validation file (or database) and the extract mode if a<br />

portion of the data should be returned as a response.<br />

Entry Fields:<br />

Select Validation Field Extract Method: These two radio buttons<br />

specify the locating method for the Validation ID field. This field is the<br />

one used to match the entry data for validation. The extract method is<br />

either Fixed Length Field or Separator Character Mode. – Default is<br />

“Separator Character” mode.<br />

Fixed Length Field Mode: Start Position:. This field is used to<br />

indicate the start column of the first character in the Fixed Length field<br />

to extract. The range is 1-110, - No default.<br />

Fixed Length Field Mode: Field Length: This field is used to specify<br />

the length of the fixed length field. Range is 1-110.<br />

Separator Character Mode: Field Separator Character:.. This field<br />

specifies the special separator character used to extract the data. Default<br />

is’,’ (comma).<br />

Separator Character Mode: Field Number:. This field indicates the<br />

field number of the data to extract. Range 1-110. Default is ‘1’.<br />

Extract Validation <strong>Data</strong> (from <strong>Data</strong> source) . These fields will be<br />

enabled if “Extract <strong>Data</strong> From Validation Record” was checked on the<br />

previous screen.<br />

Fixed Length Field Mode: Start Position:. This field is used to<br />

indicate the start column of the first character in the Fixed Length field<br />

to extract. The range is 1-110, - No default.<br />

Fixed Length Field Mode: Field Length: This field is used to specify<br />

the length of the fixed length field. Range is 1-110.<br />

Separator Character Mode: Field Separator Character:.. This field<br />

specifies the special separator character used to extract the data. Default<br />

is’,’ (comma).<br />

Separator Character Mode: Field Number:. This field indicates the<br />

field number of the data to extract. Range 1-110. Default is ‘1’.<br />