Setup 3<br />

Softwares<br />

and Web servers 3<br />

OFS data server software<br />

Setup<br />

Ethernet TCP/IP<br />

7<br />

4<br />

OFS Station<br />

(V3.0)<br />

1<br />

Databases<br />

7<br />

2<br />

5<br />

symbols.xvm (Unity Pro)<br />

symbols.prj (Concept)<br />

symbols.scy (PL7)<br />

Ethernet TCP/IP<br />

3<br />

Quantum<br />

6<br />

Premium<br />

8 Unity Pro project station<br />

3<br />

Momentum<br />

TSX Micro<br />

OFS software can be integrated into control system architectures such as the one<br />

shown above:<br />

1 PC running OFS software including the OPC Server.<br />

2 PC running the Client application, which accesses the PLC data via OFS.<br />

3 Communication networks linking the PC, running OFS software, with the PLCs.<br />

4 OPC communication protocol.<br />

5 Modbus on TCP/IP communication protocol.<br />

6 Uni-TE on TCP/IP communication protocol.<br />

7 OFS software program accesses Unity Pro project variables directly. Additionally,<br />

it conducts a check to verify that these variables are consistent with those of the<br />

Premium or Quantum PLC.<br />

Depending on the usage, the Client application and OFS software can be located on<br />

the same PC or on two different PCs 1 and 2, linked by a TCP/IP Ethernet network 7.<br />

Nota : Depending on the software used for Modicon PLCs:<br />

- PL7 software generates PLC variable symbol export files. These export files (symbols.scy)<br />

should be integrated in the OPC Server.<br />

- Concept: the variables can be accessed directly in the project (file.prj) of the Concept<br />

application. This direct link requires Concept (version > V2.0) to be installed on the OFS station 1.<br />

- Unity Pro programming software generates export files from PLC variable symbols. These<br />

export files (.xvm symbols) should be integrated into the OPC Server when the Unity Pro project<br />

development station 8 is not accessible via the OFS station. If the Unity Pro project station is<br />

permanently accessible via the OFS station, the former exchanges directly with the variables of<br />

the Unity Pro project (via P. server).<br />

Presentation:<br />

page 3/38<br />

Functions:<br />

page 3/40<br />

Reference numbers:<br />

page 3/41<br />

3/39