Infrared measuring probe: -18 ... +260°C;for small sized components(Measuring zone-Ø 2.5mm)Low price infrared technology for non-contact and quick response surfacetemperature measurements from -32 up to +760°C (ST80).or high temperature range or stationary application please refer to page 11, 77all devices with laser pointing appliancePhoto shows GIM 1826 with GTH1160 GIM1840-ST20, GIM1840-ST30 GIM1840-ST60, GIM1840-ST80INRARED MEASURING PROBEGIM 1826Specification:Measuring range: -18 ... +260 °CResolution: 0.1°CAmbient temperature range: 0 ... +65 °CAccuracy: ± 2 % of measured value or ± 2 °CRepeat accuracy: ±1% of meas. value or ±1°CResponse time (t95): 1 secondRate of emission: set permanently to 0,95Measuring zone-Ø: Ratio measuring zone-Ø :distance approx. 1:4, ie by reducing the distancebetween unit and measured object the measuringzone Ø is also reduced (eg 50 mm Ø at a distanceof 200 mm, 25 mm Ø at a distance of 100mm etc.).Relative humidity: max. 95% at 30°C,non-condensing.Storage temperature: -25 to +70 °CPower supply: 9V-battery type IEC 622(included). Automatic battery disconnectionafter a few minutes. Automatic battery disconnectionswitched off for stationary permanentoperation and 12 V DC operational voltage.Battery service life: approx. 50 hours.Dimensions: approx. 180 x 30 x 50 mm (H x W x D).Weight: approx. 180 gScope of supply: measuring probe withbattery, operating manualUnits suitable: for connection to all NiCr-Ni(type K) quick-response thermometers withminiature flat-pin plug.or stationary permanent operation:additional measuring transducer board GNTP forNiCr-Ni (type K) with output 4 - 20 mA, etc.Available upon request.Min-/Max-alarm and/or relay outputs:devices for measuring transducer with volt-freerelay outputs available upon request.Accessories:GKK 252 small case(235 x 185 x 48 mm) with foam liningGKK 1100 case(340 x 275 x 83 mm) with foam liningGB 9 V spare batteryMeasuring zone diameter 2,5 7,5 14 21 33 mmExamples for application (GIM1826 / GIM1840-ST20/ST30/ST60/ST80)l PC board test (super-heated components)l Ventilation/heating/air conditioning/ civil engineering: (detection of bad insulation, leakingtubes, energy consumption, general service measurements etc.)l Electric systems, machines, units: (detection of hot spots at electric connections, heating upof motors, bearings, pumps, compressors etc.)l ood processing and testing: (temperature of food, storage rooms, processes etc.)l Medical technology, biological testing, chemical analyses: (quick-response non-contacttemperature measurements at any object/in any area, trouble-free operation even when handlingdangerous, aggressive or other media)l Industry, mechanical engineering, craft and trade: (surface measurements at rotary partssuch as rollers, drums, shafts, printing machinery, plastic welding, asphalt, concrete etc.)l Communities, road maintenance offices etc.: eg to determine if road temperature has reachedfreezing point (use of thawing salt/sand), swimming pools, class rooms etc.Non-contact infrared digital thermometer (cpl. and ready for operation)GIM 1840 - ST20GIM 1840 - ST30GIM 1840 - ST60GIM 1840 - ST80Specification: ST20 ST30 ST60 ST80Measuring ragen: -32 ... +400 °C-32 ... +545 °C-32 ... +600 °C-32 ... +760 °CResolution:0.2°C0.2°C0.1°C0.1°CTemperature display: °C or ° selectableAccuracy:±1% of measured value or ±1°C (at > 23°C);±2°C (-18...23°C); ±2.5°C (-26...-18°C); ±3°C (-32...-26°C)Repeat accuracy: < ±0.5% of measured value or ±1°CResponse time (t95): 0.5 secondsRate of emission: permanently set to 0.95 digital settings from 0.30 to 1.00Laser pointing appliance: single ray laser circle laser circle laser circleData memory: -- -- 12 measurings 12 measuringsHi-/Lo-alarm: -- -- buzzer buzzerProbe connection: -- -- for Pt1000 probes (p.r.t. page 13)Max-value memory, hold function: at ST20, ST30Max-/Min-value memory, DI/mean value, hold function: at ST60, ST80Re-call of value measured last: for ST60, ST80 onlyWorking temperature: 0 ... 50 °CPower supply: 9V-battery type IEC 622 (included)Display illumination: press key to switch on/offDimensions:approx. 135 x 40 x 195 mmWeight:approx. 320 gStorage:cpl. device with carrying bag and hand loopGIM1840-ST20, -ST30 GIM1840-ST60 GIM1840-ST80DS121DS301DS501Measuring distance 0 25 50 75 130 mmØ 38 mmat30 cmØ 75 mm Ø 132 mmatat90 cm 150 cmØ 24 mmat30 cmØ 30 mmat90 cmØ 62 mmat150 cmØ 19 mmat30 cmØ 18 mmat90 cmØ 42 mmat150 cm10
Infrared - hand-held thermometer: -30 ... 900°C (-50 ... 500°C)(GIM 3090 - MX2 and GIM 3090 - MX4)l Reliable measurements due to accuratelaser circle sight hole, optimum handlingand ease of operationl Measurements from a safe distancedue to high-performance optics.l Low initial costs due to excellent price/quality ratio.Standard types: (in stock)GIM 3090 - MX2GIM 3090 - MX4GIM 3090 - MX4/S(incl. software, RS232 computer cable and case)Options: (against upcharge, time of delivery)C close focus optik(order name: e.g. GIM3090 - MX4C)SZ low temperature version(-50 ... +500°C, order name: e.g. GIM3090 - MX4SZ)Size of meas. zone and distance with regard to meas. object:standard optic:*) Meas. distance:Measuring zone dia60 : 1 at focus pointMeasuring zone dia35 : 1 at long distance(S10-times distance of focus point)Technical description:The laser circle sight hole shows the actualmeasuring zone. The graphic display gives the trendof the last 10 measurements and the max. and min.temperatures determined during measuring. TheMX4 is equipped with inputs for thermocouples(types K and J), external power supply, an internalmemory for up to 100 meas. values as well as adigital output. In addition the MX4 memory includes amost useful table for emmision rates, listing valuesfor those 30 materials that are most commonly used.In connection with our software and a PC the MX4 ishighly suitable for test and routine measuring.Ø 25 mmfor0 mØ 19 mm *for1.15 mclose focus optic C:Ø 25 mmfor0 mØ 15.5 mmfor0.15mØ 29 mmfor1.5 mØ 6 mm *for0.3 mØ 58 mmfor2.5 mØ 23 mmfor0.5 mØ 286 mmfor10 m*) Meas. distance:Measuring zone dia50 : 1 at focus pointMeasuring zone dia12 : 1 at long distanceØ 70 mmfor1 mØ 116 mmfor1.5 mSpecification:Meas. range:Resolution:Accuracy:Consistency:(highest value shall be valid)-30,0 ... +900,0°C(for "SZ": -50,0 ... +500,0°C)0,1°C±1% of range or ±1°C(-30...0°C = ±2°C)±0.5% resp. ±1°CResponse time: t95 = 250msSpectral sensitivity: 8 - 14 µmDisplay: LCD, approx. 35 x 45 mm high,with background illuminationWorking temperature: 0 to +50°C(for laser mode: max. 45°C)Relative humidity: 10 to +95 % r.h.at 30°C (non-condensing)Storage temperature: -20 to +50°C(batteries not incl.)Voltage supply: 2x1.5V, type R6 (AA), forMX4 additional d.c. inputDimensions: 200 x 170 x 50 mmWeight: 480gEquipment:- Max and min value memory- HI-alarm: accoustic and visual- Laser circle sight hole (laser class 2)- Emission rate adjustable- Graphic displayAdditionally for MX4- Difference display- Average value (AVG)- Connection for thermocouplestypes K and J- LO-alarm: accoustic and visual- Table of materials(emission rates preset)- Internal data memory for 100measuring values- Data exchange: RS232 or 1mV/°COptions and accessories:Software (compatible to windows)GNG 09 - 7.5Vplug-in powerpackCertificate of calibration(Calibration points: 25, 100 and 200°C)Certificate of calibration(Calibration points: 25, 200 and 495°C)Other calibration points upon request !Temperature probe type K p.r.t.pages 14, 15 and 90, 9111