11.07.2015 Views

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Simple retrofit of temperature registration in coolingchambers >10m³ by means of EASYLOG.Put in position and start - the logger runs with allthe legally required settings (92/1/EWG), no cablelaying - no paper !Warranty: 2 years!made in GermanyEASYLOG 40K EASYLOG 40KH EASYLOG 40K with GWH40Kas protection from theftEASYLOG has the following standard characteristics:Accessories:n Put in position and start - the logger runs with all the legally required settings (onemeasurement every 15 minutes) or within selectable cycle between 2(4)s ... 5h.n Battery service life: 6-8 years (double service life as option!)n Storage capacity: 48.000 measuring values, sufficient for 500 days at cycle time of15 min., i.e. considerably longer than 1 year, which is required by lawn Permanent digital indication showing the following displays:The EASYLOG has been "stopped". No data will be recorded. No data available. The loggerhas been reset and can be started again.The EASYLOG is in "halt" position. No data will be recorded. The data stored are stillavailable.EBW1Level converter RS232 - EASYBUS forconnection of max. 9 EASYBUS modules(EASYLOG, EBN, EBT etc.) to PC.(Power supply EBW1: 230V/50Hz)supplies the logger while connected(EASYLOG battery will be switched off)(Temperature will be displayed. Small arrow at the upper left hand side is blinking)The logger is active. The temperature will be measured at eg. 15 minute intervals.The values obtained will be memorized.The logger is in active mode, but no data are recorded.As soon as the start delay time is over, the logger will start under the starting conditionsspecified by the pre-programmed settings.The logger is in active mode, but no data are recorded.The recording will start as soon as the temperature is between the min. and max. alarmlimits.The logger is active, but no data are recorded.As soon as the external start key has been plugged-in the recording will start.Please note: The start key can be removed as soon as the recording has started.The temperature measured has fallen below the min. alarm limit.The temperature measured exceeds the max. alarm limit.The EASYLOG battery has almost been used up and needs to be replaced.Please return logger to manufacturer.Values exceed the measuring range.Values have fallen below the min. measuring range.n Wide measuring range from -25 ... +60 °C, -50 ... +150°C or -50 ... +300°CSpecial types for ranges within -200...+600°C possible upon requestn Data safe for 10 years in case of current failure.n IP65 - splash-water proofn Integrated clockn 2 memory types can be set: loop memory, recording till memory is fulln Minimum dimensions - sturdy housingn Busable - up to 240 EASYLOG's can be connected via 2-wire line.n Remote call-up and alarm monitoring via integrated EASYBUS-interface.n Alarm switching output upon request.EBW2Level converter RS232 independant frommains supply (due to integrated 9V-battery) -EASYBUS connection of one EASYLOG.(Power supply EBW2: 9V-battery)incl. logger supply during data transfer (EASYLOGbattery will be switched off)GWH 40KWall-type mounting for simple suspension ofEASYLOG. Dimensions: approx. 70 x 70 mm.(cannot be used together with EASYLOG 40NS W).GWH 10Wall-type mounting for simple suspensionof EASYLOG (cannot be used together with EASYLOG 40NS W).EBSK01Special plug with approx. 1m cable for theconnection of one EASYLOG, EBN.. to theEASYBUS.ESK-1external starting key for the start of thelogger in the starting mode: St.Et.GSOT 40KWindows software for setting of device,data reading and printing of data stored.(incl. EASYLOG connection cable EBSK01)63

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!