11.07.2015 Views

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

e.g. flow,throughput,speed etc.Display for frequency output encodersIn accordance withEN50<strong>08</strong>1-1 andEN50<strong>08</strong>2-2 forunrestricted use inresidential and industrialareasController for frequency output encoder (2 relays)Digital display with freely adjustable scale with frequency input,min/max. value memory, RS485 interfaceGIA 1000 RApplication: measuring of flow speeds, throughput, revolutional speed ordisplay for encoder with frequency output.Specification:Measuring range: -1999 ... +9999 digit, first and last value freely adjustableResolution: any decimal point possibleAccuracy: ± 0.1 % S ± 1 digitrequency input: 0 to 9999 HzInput sensitivity: 50 mVss, 300 mVss, 2Vss, TTL (freely selectable)Sensor supply: integrated electrically isolated power supply unit forfrequency encoder: 18 V DC +/-5 %, 20 mA.Min./Max. value memory: both the highest and lowest value will be recordedTare function: (upon request). Please specify when ordering.ault indication: probe damage, probe short-circuit, values no longerwithin measuring range.Self-diagnosis: permanent self-diagnosis of deviceInterface: compatible to RS 485 (up to 16 devices linkable via one 2-wireinterface). Connection of RS 232 by means of optional GRS485.Analog output: (optional) analog output 4 to 20 mA (or 0 to 20mA,0-10V) with scale freely selectable, electrically isolated.Display: 4 digit red LED, 13 mm highront: membrane keyboard IP65. Additional sealing for panel-mounting (optional)Housing: standard rack type housing 48 x 96 x 100 mm (H x W x D)Panel cutout: 43 x 90.5 mm (H x W)Clamping terminals: screw-type/plug-in terminalsWorking temperature: 0 to 50° C (permissible ambient temperature)Power supply: 230VAC, 50/60Hz (standard - others available againstupcharge)Power input: approx. 3VAOptions - against upcharge:12VDC: Power supply: 12VDC 1)24VDC: Power supply: 24VDC 1)12VAC: Power supply: 12VAC24VAC: Power supply: 24VAC115VAC: Power supply: 115VACAnalog output 0-20mA, 4-20mA o. 0-10V - please refer to GIR1002NSTARA: Tara functionOptionen - gegen against upcharge: (only for GIR1002R)HLR1: control output for externalsemiconductor relais 12VDC (instead of relais 1)HLR2: control output for externalsemiconductor relais 12VDC (instead of relais 1 and 2)2WREL: 2 Changer (1 x Contact additional fed out as stranded wire)SWV: Setting of set-point value lockedAVE: Alarm delay selectableAccessories: please refer to GIR1002NS-S/TSuitable sensors:GDS 01 rotational speed sensorreely adjustable 2-level controller with frequency input withmin./max. alarm, 3-level controller, min./max. value memory,RS485 interfaceGIR 1002 RApplication: measuring and monitoring of flow speed, throughput, rev.speed or control and monitoring device for encoder with frequency output.Specification:Measuring range: -1999 ... +9999 digit, first and last value freely adjustableResolution: any decimal point possibleAccuracy: ± 0.1 % S ± 1 digitrequency input: 0 to 9999 HzInput sensitivity: 50 mVss, 300 mVss, 2Vss, TTL (freely selectable)Encoder supply: integrated electrically isolated power supply unit forfrequency encoder: 18 V DC ± 5 %, 20 mA.Min./Max. value memory: both the highest and lowest value will be recordedTare function: (upon request). Please specify when ordering.ault indication: probe damage, probe short-circuit, values no longerwithin measuring range.Self-diagnosis: permanent self-diagnosis of device.Interface: compatible to RS 485 (up to 16 devices linkable via one 2-wireinterface). Connection of RS 232 by means of optional GRS485.Controller configuration: (freely selectable - 9 different types available)Type 0: display Type 1: 3-level controllerType 2: 2-level controller with min./max. alarm self-clearingType 3: same as type 2, alarm has to be cleared manuallyType 4: 2-level controller with pre-selectable hysteresisType 5: same as type 4, in addition min./max. alarm, automaticallyfollowing set-point value, alarm self-clearingType 6: same as type 5, alarm has to be cleared manuallyType 7: 2-level controllerType 8: 3-level controller with pre-selectable hysteresisType 9: special type, to customer’s specifications - no adjustmentsSetting of set-point value: via front side keyboard (lockable upon request)Control range: can be limited by manufacturer upon request (pleasespecify when ordering)Setting of alarm: via front side keyboard or automatically followingAlarm delay: 0 to 99 min., pre-programmed by manufacturer.Hysteresis: digital setting of any value (depending on switch on /switch off values set). Minimum hysteresi : 1 digit.Relay: 2 volt-free relays , 1 changeover contact and 1 normally-opencontact, switching output: 10 A (ohmic load) 250 V 50/60 Hz.Please specify preferred relay fault position (sensor not working): open (standard) orclosed. The second relay is principally energised (eg for type 2); in case of alarm (i.e.values above/below min./max. value set) the contact will be broken.Semiconductor relay: if desired, one or two relays can be taken out to allowcontrol of one or two external semiconductor relays (eg 25A). Control voltage 12V DC for external semiconductor relay will then be provided. (refer to options)Display: 4 digit red LED, 13 mm highront: membrane keyboard IP65. Additional sealing for panel-mounting (optional)Housing: standard rack type housing 48 x 96 x 100 mm (H x W x D)Panel cutout: 43 x 90.5 mm (H x W)Clamping terminals: screw-type/plug-in terminalsWorking temperature: 0 to 50° C (permissible ambient temperature)Power supply: standard 230 V AC 50/60 Hz, approx. 3 VA,Options against upcharge: please refer to GIA1000RVISION 20<strong>08</strong> low measuring transducercpl. with 1m of cable. (for more technical data p.r.t. page 85)Switching distance: 2 mm (front-panel installation possible)Supply:10 - 30 V DCSwitching frequency: max. 800 HzCable: 6 m PVC-cable 3 x 0.14²Rotor-position scanning: hall effect sensorMeasuring range: 0,5 - 25 l/minResolution:approx. 1000 pulses/lMeasuring agent: clean liquids, we recommend filtering withapprox. 20 to 40 micron.45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!