Catalog 08-2001 without prices - nl3prc
Catalog 08-2001 without prices - nl3prc
Catalog 08-2001 without prices - nl3prc
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Humidity meas. transducer, humidity/temperature meas. transducerType: GRHUHumidity measuring transducerType: GHTUHumidity/temperature measuring transducerGeneral:The measuring transducer GHTU is equipped with 2 separate measuringtransducers for humidity and temperature.Specification : (humidity: GRHU... or GHTU...)Humidity sensor: capacitive thin-film polymer sensorMeasuring range humidity: 0 to 100% relative humidity - sensor maybesubjected to condensing, rec. range: 30 to 80% r.h. (for standard sensor).or higher or lower range choose option “high-humidity sensor”,recommended range for high-humidity sensor: 5 to 98% r.h.(When ordering option high-humidity sensor, please make sure to specifymain measuring range: eg 0 to 40% r.h. or 60 to 95% r.h. etc.)Other measuring ranges available (option) against upcharge.Accuracy:Linearity: standard sensor: ±2% from 30 ... 80 % r.h.high-humidity sensor: ±2% from 11 ... 90 % r.h.Hysteresis: standard sensor: ±1.5% r..high humidity sensor: ±1% r..Specification: (temperature: for GHTU only...)Temperature sensor: platinum resistance thermometer Pt100Measuring range temperature: 0 ... 70°C (standard)OPTION: -30 ... +40°C, others upon requestAccuracy temperature: acc to DIN 751 DIN cl. B ±0.3°C at 0°C(standard tolerances) - other accuracies available optionallyGRHU - 1K, GHTU - 1KGRHU - 2K, GHTU - 2Ksame as GRHU - 1K, butsensor tube protrudingcentrally pointing downwardat a 90° angle (e.g. for directmounting to level ducts)Bronze filterGRHU - 2K,GHTU - 2KGRHU - 1R,GHTU - 1RGRHU - 1K,GHTU - 1KSpecification: (GRHU... and GHTU...)Output signal: 4-20mA (2-wire) or 2 * 4-20mA (2-wire)optionally available 0-1V and 0-10V (3- or 4 wire)(other output signals upon request)Auxiliary energy: 12 ... 30 V DC or 18 ... 30 V DC for output: 0-10VReverse voltage protection: 50V permanentlyPermissible impedance (at 4-20mA): R A [Ð] = Vs [V] - 12V / 0.02 APermissible load (at 0-1(10)V): R L [Ð] > 3000ÐWorking temperature electronics: 0 ... +70 °CWorking temperature sensors: 0 ... +70 °C (standard humidity sensor)-30 ... +110°C (standard humidity sensor with OPTION high temperature)-30 ... +140°C (high humidity sensor with OPTION high temperature)Storage temperature: -20 ... +70 °CRelative humidity (electronics): 0 ... 98 % r.h. (non- condensing)If there is a risk of condensation due to temperature changes, please useour encapsulated or lacquered types (optionally available).or outdoor application: please refer to heat absorption hat page 42Housing: ABS (IP65)Mounting position: sensor tube vertically pointing downwards tohorizontalSensor tube: anodised aluminium, Ø 14 mm, with screw-type bronzefilter 80 to 160 µm, nickel platedSensor length: 50 mm or 220 mm. (standard) - other length availableoptionally! Available sensor length "L": 300 mm, 400 mm, 500 mm.If device is to be operated at temperatures outside the range specified(0 to 70° C) make sure that electronics is not subjected to temperatureshigher or lower than that (eg use extra long tube to go through wall intocooling chamber, climatic chamber, open air etc.).Mounting: with mounting holes for wall mounting (accessible aftercover has been removed) or by means of plastic tube clamps, additionalwall support for direct mounting to channels, etc.Mounting distance for wall mounting: 70 x 50 mm (W x H)ixing screws for wall mounting: max. shaft-Ø 4 mmElectric connection: elbow-type plug acc. to DIN 43650 (IP65), max.wire cross section: 1.5 mm², wire Ø from 4.5 to 7 mmor outdoor application:Make sure to use special humidity measuring transducers withheat absorption hats. (Head absorption hat p.r.t. page 42)Make sure to use special humidity/temperature measuringtransducer with heat absorption hats.GRHU - 1R,GHTU - 1RPrices (standard types):GRHU - 1R (sensor tube at the side, L = 50mm)GRHU - 1K (sensor tube at the side, L = 220mm)GRHU - 2K (sensor tube pointing downwards, L = 220mm)GHTU - 1R (sensor tube at the side, L = 50mm)GHTU - 1K (sensor tube at the side, L = 220mm)GHTU - 2K (sensor tube pointing downwards, L = 220mm)Prices (options): (<strong>prices</strong> stated are net <strong>prices</strong> - no quantity discount possible)-HO: High-humidity sensorupcharge:(for humidity measuring < 30 % r.h. and > 80 % r.h.)-HT: high temperatureupcharge:(-30...+110°C, or -30...+140°C for high humidity sensor)-LACK: Encapsulated PC boardupcharge:-L300, L400, L500:upcharge:(Extra long sensor tube - no interim lengths possible)-AV01: output signal 0-1V for GRHUupcharge:-AV010: output signal 0-10V for GRHU upcharge:-MB...: Any measuring range for GRHU upcharge:(please state desired measuring range)-AV01: output signal 0-1V for GHTUupcharge:-AV010: output signal 0-10V for GHTU upcharge:-MB...: Any measuring range for GHTU upcharge:(please state desired measuring range)-VO: on-site display for humidity orupcharge:temperature (for output signal 4-20mA, auxiliary energy Uv = 17 ... 30 V DC)-SHUT: Heat absorption hatOrder code (examples):upcharge:GRHU-1R / MB 20-90%: GRHU-1R, 4-20mA = 20-90%GRHU-2K / AV01, L300: GRHU-2K, 0-10V = 0-100%, L = 300 mmGHTU-1K / HO, HT, LACK: GHTU-1K, 4-20mA, high temperature and highhumidity design-type, encapsulated PC board78