11.07.2015 Views

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Humidity meas. transducer, humidity/temperature meas. transducerType: GRHUHumidity measuring transducerType: GHTUHumidity/temperature measuring transducerGeneral:The measuring transducer GHTU is equipped with 2 separate measuringtransducers for humidity and temperature.Specification : (humidity: GRHU... or GHTU...)Humidity sensor: capacitive thin-film polymer sensorMeasuring range humidity: 0 to 100% relative humidity - sensor maybesubjected to condensing, rec. range: 30 to 80% r.h. (for standard sensor).or higher or lower range choose option “high-humidity sensor”,recommended range for high-humidity sensor: 5 to 98% r.h.(When ordering option high-humidity sensor, please make sure to specifymain measuring range: eg 0 to 40% r.h. or 60 to 95% r.h. etc.)Other measuring ranges available (option) against upcharge.Accuracy:Linearity: standard sensor: ±2% from 30 ... 80 % r.h.high-humidity sensor: ±2% from 11 ... 90 % r.h.Hysteresis: standard sensor: ±1.5% r..high humidity sensor: ±1% r..Specification: (temperature: for GHTU only...)Temperature sensor: platinum resistance thermometer Pt100Measuring range temperature: 0 ... 70°C (standard)OPTION: -30 ... +40°C, others upon requestAccuracy temperature: acc to DIN 751 DIN cl. B ±0.3°C at 0°C(standard tolerances) - other accuracies available optionallyGRHU - 1K, GHTU - 1KGRHU - 2K, GHTU - 2Ksame as GRHU - 1K, butsensor tube protrudingcentrally pointing downwardat a 90° angle (e.g. for directmounting to level ducts)Bronze filterGRHU - 2K,GHTU - 2KGRHU - 1R,GHTU - 1RGRHU - 1K,GHTU - 1KSpecification: (GRHU... and GHTU...)Output signal: 4-20mA (2-wire) or 2 * 4-20mA (2-wire)optionally available 0-1V and 0-10V (3- or 4 wire)(other output signals upon request)Auxiliary energy: 12 ... 30 V DC or 18 ... 30 V DC for output: 0-10VReverse voltage protection: 50V permanentlyPermissible impedance (at 4-20mA): R A [Ð] = Vs [V] - 12V / 0.02 APermissible load (at 0-1(10)V): R L [Ð] > 3000ÐWorking temperature electronics: 0 ... +70 °CWorking temperature sensors: 0 ... +70 °C (standard humidity sensor)-30 ... +110°C (standard humidity sensor with OPTION high temperature)-30 ... +140°C (high humidity sensor with OPTION high temperature)Storage temperature: -20 ... +70 °CRelative humidity (electronics): 0 ... 98 % r.h. (non- condensing)If there is a risk of condensation due to temperature changes, please useour encapsulated or lacquered types (optionally available).or outdoor application: please refer to heat absorption hat page 42Housing: ABS (IP65)Mounting position: sensor tube vertically pointing downwards tohorizontalSensor tube: anodised aluminium, Ø 14 mm, with screw-type bronzefilter 80 to 160 µm, nickel platedSensor length: 50 mm or 220 mm. (standard) - other length availableoptionally! Available sensor length "L": 300 mm, 400 mm, 500 mm.If device is to be operated at temperatures outside the range specified(0 to 70° C) make sure that electronics is not subjected to temperatureshigher or lower than that (eg use extra long tube to go through wall intocooling chamber, climatic chamber, open air etc.).Mounting: with mounting holes for wall mounting (accessible aftercover has been removed) or by means of plastic tube clamps, additionalwall support for direct mounting to channels, etc.Mounting distance for wall mounting: 70 x 50 mm (W x H)ixing screws for wall mounting: max. shaft-Ø 4 mmElectric connection: elbow-type plug acc. to DIN 43650 (IP65), max.wire cross section: 1.5 mm², wire Ø from 4.5 to 7 mmor outdoor application:Make sure to use special humidity measuring transducers withheat absorption hats. (Head absorption hat p.r.t. page 42)Make sure to use special humidity/temperature measuringtransducer with heat absorption hats.GRHU - 1R,GHTU - 1RPrices (standard types):GRHU - 1R (sensor tube at the side, L = 50mm)GRHU - 1K (sensor tube at the side, L = 220mm)GRHU - 2K (sensor tube pointing downwards, L = 220mm)GHTU - 1R (sensor tube at the side, L = 50mm)GHTU - 1K (sensor tube at the side, L = 220mm)GHTU - 2K (sensor tube pointing downwards, L = 220mm)Prices (options): (<strong>prices</strong> stated are net <strong>prices</strong> - no quantity discount possible)-HO: High-humidity sensorupcharge:(for humidity measuring < 30 % r.h. and > 80 % r.h.)-HT: high temperatureupcharge:(-30...+110°C, or -30...+140°C for high humidity sensor)-LACK: Encapsulated PC boardupcharge:-L300, L400, L500:upcharge:(Extra long sensor tube - no interim lengths possible)-AV01: output signal 0-1V for GRHUupcharge:-AV010: output signal 0-10V for GRHU upcharge:-MB...: Any measuring range for GRHU upcharge:(please state desired measuring range)-AV01: output signal 0-1V for GHTUupcharge:-AV010: output signal 0-10V for GHTU upcharge:-MB...: Any measuring range for GHTU upcharge:(please state desired measuring range)-VO: on-site display for humidity orupcharge:temperature (for output signal 4-20mA, auxiliary energy Uv = 17 ... 30 V DC)-SHUT: Heat absorption hatOrder code (examples):upcharge:GRHU-1R / MB 20-90%: GRHU-1R, 4-20mA = 20-90%GRHU-2K / AV01, L300: GRHU-2K, 0-10V = 0-100%, L = 300 mmGHTU-1K / HO, HT, LACK: GHTU-1K, 4-20mA, high temperature and highhumidity design-type, encapsulated PC board78

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!