11.07.2015 Views

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Paperless Recorder / Videographic RecorderPaperless recorderUniversal recorder for standard signals, resistor thermometersand thermocouples with up to 6 channels.Electronic recording replaces usual recordings on paper andtherefore saves consumption material. urthermore therecorded data can easily be processed by a PC.EcoGraph 3k3-channel recorderEcoGraph 6k6-channel recorderSpecification:Measuring inputs: universally programmable forDirect voltage: 0...0.1V, 0...0.2V, 0...1V, 0...10V, ±1V, ±10VDirect current: 0..20mA, 4...20mA, ±20mAResistance thermometer: Pt 100, Ni 100, Pt 500, Pt 1000Thermocouples: Type B, E, J, K, L, N, R, S, T, U, W3 and W5Input impedance: S1MOhm at voltage, 50Ohm at currentConnection of RTDs: 2-/3- or 4-wire connectionMeasuring range: programmableNumber of measuring points: 3 or 6, electrically isolatedRecording cycle: 250ms / channelDisplay: STN colour graphic display with 126mm screen diagonal,320 x 240 Pixel.Operation/Configuration: via 6 frontside keys and display dialogues.Remote Operation: configuration and archiving of settings perdisk or via backside mounted serial interface by means of PCsoftwareReadWIn ®Measurement recording: to integrated flash memory or to diskrecording length: 3 channel: 23m (memory), 43m (disk)6 channel: 14m (memory), 26m (disk)recording rate: ("feed rate") selectable,0-5-10-20-60-120-240-300-600-1000 mm/hDigital input: 4 additional operational inputsSwitching outputs: 3 change over Relais 230VAC/3A for alarmmonitoringInterface: galv. isolated serial RS232 / RS485 interface,selectable device address.Ambient temperature: 0 ... +50°CRelativ humidity: 10 ... 75 % r.., <strong>without</strong> condensationHousing: for panel mounting 144 x 144 mmMounting depth: approx. 210 mmIngress protection: front IP54, rear IP20Positioning requirement: 90 ±30° according to DIN16257Voltage supply: 93...264VAC, 48...63Hz, 20VAConnection: reverse connect protected screw-type plug connectorsThe videographic recorder that savesUniversal videoraphic recorder for standard signals, resistorthermometers and thermocouples with up to 16 channels.Electronic recording replaces usual recordings on paper andtherefore saves consumption material. urthermore therecorded data can easily be processed by a PC.MemoGraph 8k8-channel recorderMemoGraph 16k16-channel recorderSpecification:Measuring inputs: Multi functional inputs forDirect voltage: 0...1V, 0...10V, ±20mV, ±50mV, ±100mV,±200mV, ±1V, ±2V, ±5V, ±10VDirect current: 0...20mA, 4...20mA, ±1mA, ±2mA, ±4mA,±20mA, ±40mAResistance thermometer: Pt 100, Ni 100, Pt 500, Pt 1000Thermocouples: Type B, J, K, L, N, R, S, T, U, W3 and W5Input impedance: S1MOhm at voltage, 50Ohm at currentConnection of RTDs: 2- or 3-wire connectionMeasuring range: programmableNumber of measuring points: 8 or 16, electrically isolatedRecording cycle: 125ms / channelAccuracy: 0.25% S ±1 digitDisplay: STN colour graphic display with 145mm screen diagonal,320 x 240 Pixel.Operation/Configuration: via 6 frontside keys and display dialoguesor via front- and backside mounted serial interface RS232.Remote Operation: configuration and archiving of memorysettings via backside mounted serial interface by means of PCsoftwareReadWIn, e.g. by means of Modem.Measurement recording: to integrated flash memory or to diskMemory cycle: 1s/2s/3s/5s/10s/15s/30s/1min"2min/3min/6minMemory size: depending on channel count memory cycle, e.g.4 channels: 25.9 days (intern) or 42.3 days (disk) at cycle = 30sec.8 channels: 15.6 days (intern) or 25.4 days (disk) at cycle = 30sec.16 channels: 7.8 days (intern) or 12.7 days (disk) at cycle = 30sec.Switching outputs: change over Relais 230VAC/3A for alarm monitoringAmbient temperature: 0 ... +50°CRelativ humidity: 10 ... 75 % r.., <strong>without</strong> condensationHousing: for panel mounting 200 x 144 mmMounting depth: approx. 211 mmIngress protection: front IP54, rear IP20Positioning requirement: 90 ±30° according to DIN16257Voltage supply: 90...253VAC, 50/60z, max. 14VAConnection: reverse connect protected screw-type plug connectors71

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!