11.07.2015 Views

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Temperature-measuring transducer 4-20mA, Pt100, 3-wirefor head and rail case mountingPanel-mounted-resistance thermometer with or <strong>without</strong> measuring transducer GKM..PGKM..P-advantages:• low-price and compact for installation in DIN-connection head form B• adjustable measuring range (from -50 to +400°C with only three basic types)• high accuracy• large ambient temperature range• error message in case of sensor damage or sensor short-circuit• functional warranty 5 years• conforming toSpecification: (GKM..P)Measuring ranges: several values in the range from -50 to 400°C.Measuring range can be set by customer (or will be calibrated by ourworks, if desired). 3 design-types are available:- GKM1P: -50...+50°C, 0...50°C, 0...100°C, 0...120°C, 0...150°C u. 0...200°C- GKM2P: -50...+200°C, 0...200°C, 0...250°C, 0...300°C, 0...350°C u. 0...400°C- GKM3P: -30...+30°C, -30...50°C, 0...60°C, 0...80°C, 0...100°C u. 0...120°COther ranges upon request.Selection of measuring range: via soldering jumpers, fine-tuning bymeans of 2 potentiometers (zero point "Z" and span "SP")Linearisation: linear to temperature acc. to DIN IEC 751Meas. current: approx. 0,8 mAPerm. resistance of connection cable: RL = 30 Ohm overall resistanceEffect of sensor connection line: ±0,2 K / 10 Ohm (for 3-wire connection);for 2-wire connection: line resistance will be deemed as faultOutput signal: 4 - 20 mAAuxiliary energy: V s 10 … 30 V DC, permissible ripple factor 10%Perm. load R A : R A R (V s - 10 V ) / 0,02 A [R A in Ohm, V s in V]Load diagram:Load R A[Ohm]GT103/GKM..PGKM-insert withPt100-sensorof GT103/GKM6Alu-head orplastic(upon request))LV Sin VoltLinearity fault: ± 0,1 % of meas. span setTemperature effect: ±0,01% / K or ±0,02 °C / K (Z);±0,02 % / K (span)Load effect: 0,05 % / 100 OhmSensor damage: making contact < 3mA,or breaking contact >23.5mA if only one line is openSensor short-circuit: making contact < 3mA,or temperature meas. value if short-circuit occurs between lines 2 and3 (equiv. to Pt100 in 2-wire connection circuit)Electromagnetic compatibility (EMC):conforming to acc. to DIN EN 50<strong>08</strong>2-2Electric protection: no polarity at outputOperating and storage temperature: -40 … +85°CRelative humidity: DIN IEC 68 2-30 var.2 0... 95 % r.h., (non-condensing)Vibration: DIN IEC 68 2-6 10…2000 Hz 5 gShock: DIN IEC 68 2-27 g n = 15Housing: polyamide, glass fibre reinforced, IP50Connection terminal: IP00, connection cross section 0,14 ... 1,5 mm²Weight: approx. 30 g Warranty: functional warranty 5 yearsDimensions:GKM1P (for customer setting)(small measuring ranges: from -50 to +200°C)GKM2P (for customer setting)(large measuring ranges: from -50 to +400°C)GKM3P (for customer setting)(HKL measuring ranges: from -30 to +120°C)GKM..P / WE (set by our works)(please specify measuring range desired on your order!)Rail adapter upcharge:(for snap-on to top-hat railGT103 / GKM (p.r.t. page 92)Panel-mounted resistance thermometerPt100 cpl. with measuring transducer GKM..P - measuring transducerand Pt100 can be taken out in form of an insert (price valid forstandard length 100mm and temperature range as to customer'sspecification between -50 and +400°C (depending on the measuringranges possible for the GKM..P devices))Special designs upon request - please contact us!Ordering data required if device is to be set at our works:GKM1P (0 to 200°C) or GKM2P (0 to 400°C) or GKM3P (-30 to +50°C).Please note that the GKM..P allows a limited number of rangesonly; 4-20 mA is standard, alterations not possible.(Any range that has not been mentioned here upon request!)or any range or output please refer to our types GTP or GTMU.Please contact us.74

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!