EASYBUS PC-MasterEASYBUS PC-Masters represent the interface betweensensor module, EASYBUS and PC. To meet customersvarious requirements the following options are available:EBW 9n level converter RS232 - EASYBUSn current supply for up to 9 sensor modulesn Software EBS 9MEBW 64n level converter RS232/RS485 - EASYBUSn current supply for up to 64 sensor modulesn Software EASYControlEBW 240Components or The EASYLOG Remote Operation Systemn level converter RS232/RS485 - EASYBUSn current supply for up to 240 sensor modulesn Software EASYControlMODEM 1000 analog standard industry-MODEM with passwordprotection for the EASYBUS remote data transfer via analog telephone nets.(incl. mains adapter, telephone cable, 25 pole DSub cable and GSA 25S-9B)MODEM 2000 HS analog hat rail MODEM with password protectionand SMS alarm for the EASYBUS remote data transfer via analog telephone nets.(supply voltage: 10..60VDC, incl. telephone cable and 9 pole DSub cable)MODEM 3000 GSM GSM MODEM for mobile 900 MHz telephone netswith password protection and SMS alarm for the EASYBUS remote data transfer via 900MHz mobile nets.(supply voltage: 10..60VDC, incl. 9 pole DSub cable, antenna has to be ordered separately)Antenne 3000 GSM dual band industry antenna with fasteningGNG 12/300 Hat rail mains adaptor suitable for MODEM2000HS / 3000GSMGNG 12 - LE plug-in power supply suitable for MODEM2000HS / 3000GSMGSK 9S-9S-NM 9 pole null modem cable to connecta MODEM to EBW1 ... EBW240 level convertersGRS 01/9 - NM interface adapter to connecta MODEM to EB2000 MC level convertersSpecification:Voltage supplyPower consumptionMax. permissible numberof sensor modulesPermissible cable length*Baud rateAmbient conditionsOperating temperatureStorage temperatureHumiditySerial interfaceElectr. isolatedOverload displayShort-circuit proofDimensions (H x W x D)EBW 240230V/50Hzapprox. 30W2401000m4800 Baud0..55°C-20..+60°C20-80% noncondensingRS232 orRS485yesyesyes85x200x240mm(<strong>without</strong> supply)* depending on type of cable and wiringEBW 64230V/50Hzapprox. 15W641000m4800 Baud0..50°C-20..+60°C20-80% noncondensingRS232yesyesyes100x75x110mmEBW 1230V/50Hzapprox. 5W9200m4800 Baud0..50°C-20..+70°C20-80% noncondensingRS232yesnoyes112x80x45mmEASYControlSoftware for recording, monitoring, display and documentationof up to 240 sensor modules of the EB-series or 15 GIA/GIR ...devices:nnnnnnnnnnnnnnnmin./max. value monitoring for each measuring pointstraightforward display of current measuring values in form of tablesimple sorting of sensor module sequ. by means of drag and dropscanning cycle for each sensor module can be individually selectedadding and deleting of sensor modules during recording operationdisplay of measuring values as diagram or tableseparate fault listmemorizing, filing of measuring data, fault lists and settingsautomatic detection of new sensor modulesautomatic system initializationautomatic detection of all sensor modules connectedfully automatic assignation and administration of bus addressesaut. detection of sensor module type, meas. range and meas. unitalarm supervision with EBB4out module (each one relais: min-, maxalarm,alarm in general)also suitable for monitoring up to 15 GIA/GIR devices (functions limited ifoperating with GIA/GIR).Note: simultaneous connection if GIA/GIR... and EASYBUS modules is not possible!68The only thing left for you to do is entering your description!
Accessories:EASYBUS - accessoriesSensor modules p.r.t. pages 60, 61, 62 as ofLogger p.r.t. pages 63, 64, 65 as ofEBSK 01 special plug with approx. 1 m of cable for connection of one EASYLOG , EBN.. to the EASYBUSEBSK 03 special plug with approx. 3 m of cable for connection of one EASYLOG , EBN.. to the EASYBUS(Please note: EASYLOG and EBN.. will be supplied <strong>without</strong> connection cable. The GSOT40K includes a connection cable EBSK01.Please order EBSK01 resp. EBSK03 as required in case of permanent bus connection!)ESK-1 external starting key, independant from mains supply, to start logger in the starting mode St.Et(Power supply: 9VDC - via integrated 9V-battery, dimensions: 107 x 62 x 26.5 mm (H x W x D))Examples for application: In the office the EASYLOG will be set for monitoring functions by means of the GSOT40K; it will be prepared tostart by setting it to "external Start (St.Et)". After the logger has been taken to the site of application the starting keywill be connected. Press relevant button to start logger. The starting key may now be removed again.GWH 40K wall suspension with lock as protection against theft - see picture page 63suitable for all EASYLOG 's (with the exception of EASYLOG 40NS W), EBN/K - ... and GIA0420WKGWH 10 simple wall suspension, made of stainless steel, for all EASYLOG's - except EASYLOG 40NS WMount wall suspension at the monitoring point; EASYLOG may now be easily put inEBW 1 converter 230V~ for connection of max. 9 modules to a PCConverter RS232 - EASYBUS, for the connection of max. 9 modules to the RS232-interface (9-pin Dsub-plug) of your PC.Power supply: 230VAC / 50Hz, dimensions: 112 x 80 x 45 mm (H x W x D) - p.r.t. page 63(Scope of suppyl incl. 9-pin Dsub-extension cable. Please note: order Dsub9 -> Dsub25, if required! - GSA 9S-25B)EBW 2 converter for the connection of one module to a PC - independant from mains supplyConverter RS232 - EASYBUS - independant from mains supply - for the connection of one module (e.g. EASYLOG ) to the RS232-interface (9-pin Dsub-plug) of your PC. Power supply: 9VDC - via intergrated 9V-battery, dimensions: 107 x 62 x 26.5 mm (H x W x D)(Scope of supply incl. 9-pin Dsub-extension cable. Please note: order Dsub9 -> Dsub25, if required! - GSA 9S-25B)EBW 9 set consisting of converter EBW1 and recording software EBS9MEBW 64 converter for connection of max. 64 modules to the RS232 interface of a PC(Scope of supply incl. 9-pin Dsub-extension cable, Dsub-adapter GSA9S-25B and recording, monitoring and display softwarefor up to 240 sensor modules: EASYControl)EBW 240 converter for connection of max. 240 modules to the RS232 interface of a PC(Scope of supply incl. 9-pin Dsub-extension cable, Dsub-adapter GSA9S-25B and recording, monitoring and display softwarefor up to 240 sensor modules: EASYControl)GSA 25S-9B connection-adapter: 25-pin Dsub-plug 9-pin Dsub-socketGSA 9S-25B connection-adapter: 9-pin Dsub-plug 25-pin Dsub-socketEB 2000 MC EASYBUS-display and monitoring device for 9 channels, incl. level converter PC - EASYBUSGRS 01/9 interface cable for EB2000 MC for connection to 9-pin RS232 interface of a PC - adapterGSA 9S-25B to snap on to 25-pin PC interface will also be suppliedGRS 01/9 - NM interface adapter to connect a MODEM to EB2000 MC level convertersMODEM 1000 analog standard industry-MODEM with password protection for the EASYBUS remote datatransfer via analog telephone nets. (incl. mains adapter, telephone cable, 25 pole DSub cable and GSA 25S-9B)MODEM 2000 HS analog hat rail MODEM with password protection and SMS alarm for the EASYBUS remotedata transfer via analog telephone nets. (incl. telephone cable and 9 pole DSub cable - for power supply p.r.t. page 68)MODEM 3000 GSM GSM MODEM for mobile 900 MHz telephone nets with password protection and SMS alarmfor the EASYBUS remote data transfer via 900MHz mobile nets. (incl. 9 pole DSub cable, antenna and power supply has to be ordered separately)Antenne 3000 GSM dual band industry antenna with fasteningGSK 9S-9S-NM 9 pole null modem cable to connect a MODEM to EBW1 ... EBW240 level convertersVSL 2P twisted special cable for EASYBUS-system, cross section 2 x 0,75 mm²AKL 1P special branch terminal for connection to VSL2P, 2 piecesEBS 9M Windows-software for recording and archiving of max. 9 sensor modules - p.r.t. page 40EASYControl Windows-software for recording, monitoring and archiving of max. 240 sensors ofthe EB-series - p.r.t. page 68EBB 4 out EASYBUS switching module for alarm supervision in connection with EASYControlHat rail mounting, 4 relais (changer), supply voltage 230VACEASYBUS.dll Windows-function library for interface communication EASYBUS - PC, to write yourown programmesGSOT 40K Windows-software for EASYLOG for settings, data read-out and printing of logger data(diagram or table), p.r.t. page 66. incl. EASYLOG-connection cable EBSK01per m69