11.07.2015 Views

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

Catalog 08-2001 without prices - nl3prc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Ø9.0mmTemperature-measuring transducer cpl. with Pt100 or NiCr-Ni (type K) sensorGTMUdesign-type 1GTMUdesign-type 2GTMUdesign-type 3GTMUdesign-type 4GTU-2R-OMU designer housing for ambienttemperature sensing housing <strong>without</strong> transmitter,incl. Pt100 Sensor 2-,3- or 4-wire, Pt1000 upon requestStandard:G = ½"L = 100mmD = 6mmStandard:G = ½"HL = 50mmL = 100mmD = 6mmStandard:L = 50mmD = 3mm60.0mm70.0mm26.0mm 70.0mmThis housing also maybemounted directly to aconcealed distributionbox.72GTMU design-type 5Design-type 1water-proof IP 65Versions with transmitter:GTMU design-types 1 as ofGTMU design-types 2 as ofGTMU design-types 3 and 4 as ofGTMU design-type 5 as ofelectrically isolated transmitters:GTMU/GITTupcharge:(design-type 1, 2, 3, 4 or 5 - Pt100, Pt1000 or NiCr-Ni, output 4-20mA)transmitters for outdoor usage: (-40...+70°C)GTMU/GKMupcharge:(design-type 1, 2, 3, 4 or 5 - Pt100 3-Leiter, only output 4-20mA available)Specification:Sensor elements:- resistance thermometer: Pt100 class B (higher sensor precision p.r.t page 12)- thermocouple: NiCr-Ni Klasse 1Available measuring ranges:Pt100: -200 ... +800°C NiCr-Ni: -200 ... +1372°CStandard measurings ranges:Pt100: 0...100°C, 0...200°C, -50...+50°C, -50...+150°CNiCr-Ni: 0...100°C, -50...+150°C, -200...+300°C, 0...600°C, 0...1200°COPTION: any other measuring range against upchargeAccuracy electronics: ±0.2% S (Pt100), resp. ±0.2% ±0.5°C (NiCr-Ni)Higher precision e.g. via optionally different transmitter GITT01, GKM, RT-LEX)Output signal: 4 - 20 mA (2-wire) - standardoptionally 0-1V, 0-2V, 0-5V, 0-10V (3 or 4 wire) available(only possible for GTMU types 1..5)Auxiliary energy: Vs = 12 ... 30 V DC (at 0-10V: Vs = 18 ... 30 V DC)(for special types e.g. GTMU/GITT off 8...30V)Reverse voltage protection: 50 V permanentlyAllowable burden (for 4-20mA): R A [Ð] = Vs [V] - 12V / 0.02 A(for special types e.g. GTMU/GITT p.r.t. refering page)Allowable load (for 0-__Volt): R L > 3000ÐOperating temperature electronics: 0 ... +70°C (-40...+70°C at .../GKM)Temperature coefficient: 0.01 % / °C (Pt100), 0.05% / °C (NiCr-Ni)Storage temperature: -20 ... +85 °C (-40...+85°C at .../GKM)Housing: ABS (IP65)Mounting: with holes for wall mounting (accessible after removal of cover)Mounting distance: 70 x 50 mm (W x H)ixing screws: max.shaft Ø 4 mmMounting position: anyElectric connection: elbow plug acc. to DIN 43650 (IP65), max. cablecross section: 1.5 mm², cable diameter from 4.5 to 7 mmThread dimensions „G“: 1/2“ (standard) material V2A or V4AG1/4“, G3/8“, G1/2“, M5, M6, M8, M10, M12 - Other threads upon request!Sensor tube: „D“: 3 mm, 4 mm, 5 mm, 6 mm and 8 mm - material V4ACollar tube: (for design-type 2 only) HL = specify desired length (V4A-tube)Standard:L = 100mmD = 5mmVersions <strong>without</strong> transmitter:GTU-2R-OMU as ofPt100, 2,-/3- or 4-wire, Pt1000 upon requestGTMU-OMU design-type 1 as ofGTMU-OMU design-type 2 as ofGTMU-OMU design-type 3, 4 as ofPt100, 2,-/3- or 4-wire, Pt1000 upon request, NiCr-Ni (not potential free).Potential free - p.r.t options.Sensor installation: Pt100-sensors will be electrically insulated at ourworks. NiCr-Ni-sensors are not electrically insulated as a standard(connection between sensor and outer sheathing).OPTION: electrically insulated design-type availableDesign-types:Type 1: with threaded stem “G” for direct screw connectionType 2: for extra high temperatures, threaded stem “G” at a distancefrom housing. HL = length of collar tubeType 3: indoor / outdoor probe for direct wall mounting(encapsulation of electronics required for outdoor use).Type 4: duct type probe with centrally mounted sensor tube arrangementwith the shaft of device pointing downwards at a 90° angle.Type 5: measuring transducer for Pt 100 or NiCr-Ni sensors alreadyexisting on site or for applications where sensor and housingneed to be spaced (eg. due to extremely high ambienttemperatures or to design reasons).Sensor connection: (for design-type 5)Pt 100: 2- or 3-wire connection possibleNiCr-Ni: 2-wire onlyPG 7 screwed conduit entry for sensor cable (max. outer Ø 6.5 mm),connection by screw-type terminal on PC board (max. wire Ø 1.5 mm 2 ).Ordering information: at least necessary:Type, sensor element, range, output signal and type specific sensortube data: "L" and "D" (type 1-4), "G" (type 1,2), "HL" (type 2).Ordering examples: all data to be mentioned in any case!GTMU, design-type 1, Pt100 DIN class B, 0 ... 100°C = 4-20mA, G = 1/2",L = 100mm, D = 6 mmGTMU, design-type 3, NiCr-Ni, electrically insulated, 0 ... 1200°C =4-20mA, L = 50 mm, D = 3 mmGTMU, design-type 5, Pt100, -50 ... +150°C = 0-10VOptions - upcharges:AV...: option: other output voltage upcharge:(please state desired voltage - only for GTMU type 1-5)MB...: option: any other meas. range upcharge:(please state desired measuring range)No upcharge for option -AV.., -MB if more than 10 pcs. are orderedL...: longer tube, each started further 100mm upcharge:Option: NiCr-Ni electrically insulatedupcharge:LACK: option "encapsulated PC board" upcharge:(for outdoor application, i.e. applications where condensation is possible)VO: option: on-site display upcharge:(for output signal 4-20mA, auxiliary energy Uv = 17 ... 30 V DC)Please note: types 1 - 4 are supplied cpl. with sensor, measuringtransducer etc., calibrated and thus ready for use.Type 5 does not include sensor which is either already existing at yourworks or will have to be ordered separately acc. to your specifications(p.r.t. pages 88, 91, 92)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!