8’–24’ POWERFOIL ® X2.0 & 10’–24’ POWERFOIL ® X2.0PLUS FANSIntroduction (cont.)3Fan size10 ft(3 m)12 ft(3.6 m)14 ft(4.3 m)16 ft(4.9 m)18 ft(5.5 m)20 ft(6.1 m)24 ft(7.3 m)Motor sizeHP (kW)1.0(0.75)1.5(1.1)1.5(1.1)1.5(1.1)2.0(1.5)2.0(1.5)2.0(1.5)Controllerrated HP(kW)1.0(0.75)1.5(1.1)1.5(1.1)1.5(1.1)2.0(1.5)2.0(1.5)2.0(1.5)Powerfoil ® Minimum requiredsupply circuit sizeNominal output 1Maximum full loadmotor current(as programmed) 26.7–7.4A3.9–4.3A1.9–2.3A1.3–1.4A9.2–9.7A5.3–5.6A2.5–3.0A2.0–2.1A9.2–9.7A5.3–5.6A2.5–3.0A2.0–2.1A9.2–9.7A5.3–5.6A2.5–3.0A2.0–2.1A9.2–9.7A5.3–5.6A2.5–3.0A2.0–2.1A11.4–12.1A6.6–7.0A3.0–3.6A2.7–2.8A11.4–12.1A6.6–7.0A3.0–3.6A2.7–2.8AMax RPM115RPM95RPM95RPM77RPM70RPM58RPM48RPMAirfoillength49.5 in(1.26 m)61.5 in(1.56 m)73.5 in(1.87 m)85.5 in(2.17 m)97.5 in(2.48 m)109.5 in(2.78 m)133.5 in(3.39 m)Suggesteddistance fromceiling 35 ft (1.5 m)6 ft (1.8 m)6 ft (1.8 m)7 ft (2.1 m)7 ft (2.1 m)8 ft (2.4 m)8 ft (2.4 m)1. 2. This value may vary due to input voltage conditions.3. The distance of the fan from the ceiling should be measured from the top of the winglets to the ceiling.Notes:• Remote wall interface (150-ft CAT5 cable included).• 22RF9P5AL22RF5P7AL• All models are suitable for Class A environments up to 100 m (328 ft) and Class B environments up to 5 m (16 ft).CAUTION: <strong>Big</strong> <strong>Ass</strong> <strong>Fans</strong> requires that the Powerfoil X2.0 Plus fan be supplied from one of the following types oftransformers:575V–600V models: 575V/330V Wye secondary (neutral not utilized)400V–480V models: 480V/277V Wye secondary (neutral not utilized)200V–250V models: 208V/120V Wye secondary (neutral not utilized)240V/120V Delta secondary (Wild/High Phase B)Integration into any other power distribution scheme may result in improper fan operation or premature hardware failure! Seepage 28 for more information.ATTENTION : La société <strong>Big</strong> <strong>Ass</strong> <strong>Fans</strong> exige que le ventilateur Powerfoil X2.0 soit alimenté par un des types detransformateurs suivants:Modèles 575 V – 600 V : Secondaire en étoile 575 V / 330 V (neutre non utilisé)Modèles 400 V – 480 V : Secondaire en étoile 480 V / 277 V (neutre non utilisé)Modèles 200 V – 250 V : Secondaire en étoile 208 V / 120 V (neutre non utilisé)Secondaire triphasé 240 V / 120 V (phase B haute tension)L’intégration dans tout autre schéma d’alimentation peut entraîner un mauvais fonctionnement du ventilateur ou unedéfaillance prématurée du matériel. Voir page 28 pour plus de détails.WWW.BIGASSFANS.COM ©2012 DELTA T CORP. DBA BIG ASS FAN CO. ALL RIGHTS RESERVED

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!