<strong>INSTALL</strong>ATION OF CURRENT TRANSFORMERUsed for plasma units that do not haveArc Good (Arc Xfer) signal or DCPProvided Power Resistoracross terminalsWires to ARC OKAYscrew terminals onTHC Sensor Card35 to 100A range Plasma unitsPass one conductor from the AC line straightthrough the center of the Current TransformerProvided Power Resistoracross terminalsWires to ARC OKAYscrew terminals onTHC Sensor CardLess than 35A UnitsTake a full wrap with one wire fromthe AC line.PAGE 18