PC w/MACH3Grounding practices to reduce noise and increase safetyMP3000-<strong>DTHC</strong> Interface/Control BoxNote THC Sensor Card shielded cableis not connected to any ground in the Control boxDo NOT Ground PC or Controllers toEarth Ground Rod. Conrollers will reference themselvesto power ground through their AC linesController CabinetMP3000 and UBOB have built in isolation on all inputs from the tableto prevent noise transfer and ground loopsTHC Sensor CardCNC PLASMA TABLEUse ground strap to gantry from tableTabel I/OCard(limits, homeAux relay)PLASMAUNITAttached to metalChassi#10 to #4 Ga heavy wireGantryGround Rod or Metal polein earth groundGround runs shouldbe less than 10’Grounding plate#10 to #4 Ga heavy wirePAGE 26