12.07.2015 Views

Mini-Space Series Installation, Operation & Maintenance Manual

Mini-Space Series Installation, Operation & Maintenance Manual

Mini-Space Series Installation, Operation & Maintenance Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Mini</strong>-<strong>Space</strong> <strong>Series</strong> <strong>Installation</strong>, <strong>Operation</strong> & <strong>Maintenance</strong> <strong>Manual</strong>Refer to line size charts provided below for recommendedline sizing.Total Unit*Equivalent Ft. accounts for the linear pipe length as well asequivalent length of Valves, Elbows & Tee’s as shown in the charton the previous page.Total Unit(©April, 2008)Recommended Liquid Line Sizes(For R22 or R407C Refrigerant)Receiver to Evaporator (Equivalent Ft.*)BTU/Hr 50’ 100’ 150’Capacity or less or less or less12,000 3/8 3/8 3/818,000 3/8 3/8 1/224,000 3/8 1/2 1/236,000 1/2 1/2 1/242,000 1/2 5/8 5/848,000 1/2 5/8 5/860,000 1/2 5/8 5/872,000 1/2 5/8 5/896,000 5/8 7/8 7/8Recommended Discharge Line Sizes(For R22 or R407C Refrigerant)NOTEEquivalent Length Ft*BTU/Hr 50’ 100’ 150’Capacity or less or less or less12,000 1/2 1/2 5/818,000 5/8 5/8 5/824,000 5/8 7/8 7/836,000 7/8 7/8 7/842,000 7/8 7/8 7/848,000 7/8 7/8 7/860,000 7/8 1-1/8 1-1/872,000 7/8 1-1/8 1-1/896,000 1-1/8 1-1/8 1-3/8Vertical runs are based on a total rise of 30equivalent feet. For longer sizes, individualcalculations must be made. Sizes assumethe use of single risers; double risers may benecessary.Consult the Copeland applications data guide formore detailed information regarding refrigerant linetraps and line sizing.2.7.2 Water/Glycol, Chilled Water and HotWater Reheat PipingThe piping connections for water/glycol, chilled watersystems and systems with optional hot water reheatare sweat connections. Pipe sizes may not necessarilybe the same size as the unit connection. Pipingshould be sized to match the required system pressuredrop and pump capacity (if applicable) and mayrequire reducing fi ttings to match the connection sizeon the air conditioner.Water/glycol/chilled water-cooled systems with lowentering fl uid temperatures should have insulatedpiping. The recommended ethylene glycol solutionratio is 40% glycol to 60% water. (SATS recommendsDowtherm SR1 manufactured by Dow Chemical Co.)Use only ethylene glycol with inhibitors for corrosionprotection.WARNINGGlycol is hazardous. Consult the manufacturer’sMSDS for detailed safety information.CAUTIONWhen installing and fi lling the water/glycol/chilled water loop and optional hot water reheatloop, all air must be bled from the pipingsystem.CAUTIONThe piping system must be fl ushed prior to operatingthe system. Failure to do so will resultin equipment problems.A strainer should be included in the water/glycol/chilled water line and optional hot water reheat line.Once the system is operational, the fl uid runs throughthe strainer where any foreign objects are removed.The strainer screen should be cleaned periodically.2.7.3 Pump PackageInstall a concentric reducer at the pump suction anddischarge openings and make all piping at least one-(1) size larger than the diameter of the openings. Ifa suction strainer necessary, install one with a netarea 2-3 times larger than the suction piping. Thepiping leaving the drycooler should enter the pumpsuction port. Install a check valve in the dischargeline to prevent back fl ow that may damage the pumpon shut down. Install a ball valve in the suction anddischarge lines for maintenance purposes.2-8Air Technology Systems, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!