12.07.2015 Views

Mini-Space Series Installation, Operation & Maintenance Manual

Mini-Space Series Installation, Operation & Maintenance Manual

Mini-Space Series Installation, Operation & Maintenance Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Mini</strong>-<strong>Space</strong> <strong>Series</strong> <strong>Installation</strong>, <strong>Operation</strong> & <strong>Maintenance</strong> <strong>Manual</strong>2.8 Utility Connections2.8.1 Main PowerThe <strong>Mini</strong>-<strong>Space</strong> product offering is available in singleor three phase variations and a wide range of voltages.It is imperative that the unit nameplate beexamined to determine the operating voltage, frequencyand phase of the system (see Figure 9). Thenameplate also provides the full load amps (FLA), thecurrent the unit will draw under full design load, theminimum circuit ampacity (MCA) for wire sizing, andthe maximum fuse or HACR (Heating, Air Conditioning,Refrigeration) breaker size (MAX FUSE/CKTBKR) for circuit protection. The unit’s nameplate islocated inside the cabinet within the electrical box.NOTEIf the nameplate states MAX FUSE/CKT BKR, itis required to use fuses or a HACR type circuitbreaker to protect the system. Other protectiondevices are not allowed based upon the productlisting.The unit is provided with terminals for all requiredfi e ld-wiring connections. Refer to the electrical drawingsupplied with the unit for all power and control fi eldwiring.It is important to identify the options that werepurchased with the unit in order to confi rm which fieldconnections are required.WARNINGVerify power is turned off before making connectionsto the equipment.NOTEAll wiring must conform to local and nationalelectrical code requirements. Use of copper conductorsonly is required. Wiring terminations maybecome loose during transit of the equipmenttherefore; it is required to verify that all wiringterminations are secure.It is important to verify that the main power supply coincideswith the voltage, phase and frequency informationspecified on the system nameplate. The supplyvoltage measured at the unit must be within ±10% ofthe voltage specified on the system nameplate exceptfor 208/230V single-phase units which have a differenttolerance listed in the sections to follow.A main distribution panel must be provided with amanual fused disconnect switch or HACR type circuitbreaker per local and national electrical codes forservice to the equipment. Do not mount a customersupplied manual fused disconnect switch or HACRtype circuit breaker to the surface of the A/C unit.The unit is provided with a main power pilot hole anda control wiring pilot hole for connection of the fi eldwiringconduits. Typically, these pilot holes are locatedon the side of the <strong>Mini</strong>-<strong>Space</strong> cabinet. A label stating“MAIN POWER INPUT” is placed in close proximity.Figure 8- Sample NameplateTerminate the main power wires at the line side of themain power service disconnect switch located withinthe electric box (see Figure 10). A separate equipmentground lug is provided in the electrical box for terminationof the earth ground wire.(©April, 2008)2-10Air Technology Systems, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!