12.07.2015 Views

Mini-Space Series Installation, Operation & Maintenance Manual

Mini-Space Series Installation, Operation & Maintenance Manual

Mini-Space Series Installation, Operation & Maintenance Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Mini</strong>-<strong>Space</strong> <strong>Series</strong> <strong>Installation</strong>, <strong>Operation</strong> & <strong>Maintenance</strong> <strong>Manual</strong>4.3 Field ServiceNOTEDo not attempt to make repairs without theproper tools.It may be necessary to perform repairs on the refrigerationsystem. If field repairs are necessary, thefollowing procedures apply:4.3.1 Leak DetectionSeveral methods can be used to detect a leak in therefrigeration system. The most modern and easiestmethod is to use an electronic leak detector. Followthe manufacturer’s directions and any leak canbe quickly located. A second method is to use soapbubbles. Apply a solution of soapy water with a brushor sponge to the joints and connections in the refrigerationlines. A leak in the lines will cause bubbles toform.NOTEHalogen leak detectors are ineffective withR407C refrigerant because R407C does notcontain chlorine like R22 refrigerant.4.3.2 Leak RepairWhen a leak is located, properly reclaim the remainingrefrigerant charge before beginning repairs.Adjacent piping must be thoroughly cleaned byremoving all paint, dirt and oily film. Use a wire brush,sandcloth or sandpaper and wipe the area with clean,dry cloths. Protect nearby parts from heat damage bywrapping with water-soaked cloths.4.3.3 Refrigerant PipingWhen replacing components within the cabinet of theunit, the following consumable materials are recommended:Use Silfos alloy for copper-to-copper (pipingdischarge or suction line repairs). Silver solder (Stay-Silv #45) and fl ux are to be used on copper-to-brassor copper-to-steel repairs. For liquid line repairs atthe drier, strainer, sight glass, or expansion valve,use a 95% tin to 5% antimony solder with flux.When component replacement is complete, removeall traces of flux. After any repair, pressure checkthe system and ensure there are no leaks prior torecharging the system.4.3.4 General CommonRepairs/Component Replacement4.3.4.1 Compressor FailureThe compressor is the most important componentof the air conditioner. Numerous safety devices areprovided to protect the compressor from failing.If a compressor failure has occurred, determinewhether it is an electrical or a mechanical failure.An electrical failure will be indicated by the distinctpungent odor once the system has been opened. If aburnout has occurred, the oil will be black and acidic.A mechanical failure will have no burned odor andthe motor will attempt to run, an abnormal or excessivenoise may be present.An analysis of the oil is the only way to determine theproper procedure for cleaning the refrigerant system.Acid test kits are available from several manufacturersfor measuring the acid level in the oil. These arecapable of making accurate acid measurements, butif they are not available, a check of the oil by sightand smell can give a quick indication if contaminationremains in the system. Since refrigeration oils varyin color, a sample of the new oil in the replacementcompressor should be removed prior to installationand sealed in a small glass bottle for comparisonpurposes. If the oil has been exposed to refrigerant,the bottle should not be tightly capped, since the residualrefrigerant may create a high pressure if tightlysealed and exposed to high temperature.CAUTIONAvoid touching or contacting the gas and oil withexposed skin. Severe burns will result. Use longrubber gloves in handling contaminated parts.All electrical connections should be checked toensure they are tight and properly made. Check allcircuit breakers, contactors and wiring. The contactorsshould be examined and replaced if contacts areworn or pitted.If there is acid in the oil, there has been an electricalfailure which has caused the compressor motor toburn out. The acid diffuses throughout the refrigerationsystem and must be removed by using a burnoutfi lter kit before a new compressor is placed in service.Not only must the compressor be replaced, butalso the entire refrigeration circuit must be cleaned4-9(©April, 2008)Air Technology Systems, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!