appropriate, PRV records also include remarks <strong>of</strong> special interest from an operational standpoint,such as whether a valve is equipped with some special modification to provide additionalservices for reducing pressure. In many locations, ancillary equipment has been provided to thePRVs so that the pressure setting can be controlled from the water system operations controlcenter. These modifications allow the operator to remotely adjust the valve and control the flowfrom the zone <strong>of</strong> supply.Pump StationsElevations within the <strong>Bellevue</strong> water service area range between 25 and 1450 feet. The supplyhydraulic grade line at the SPU supply connections is generally high enough to serve manyadjacent service areas; thus, several <strong>of</strong> the connections are equipped with PRVs, as discussedpreviously. During high demand periods, however, the supply gradient falls, and pumping isrequired at some connections. The operation <strong>of</strong> the pump stations is discussed later in thischapter under "Hydraulic Operations." In addition to those pump stations associated with thesupply connections, a number <strong>of</strong> areas are at elevations that require pumping <strong>of</strong> all waterdelivered to the service area, such as the South <strong>Bellevue</strong> operating area.The pumping stations are listed in Table 6-5. The table indicates the location <strong>of</strong> pump stations,the zone from which they are supplied, the zone to which they pump, the number <strong>of</strong> pumpswithin each pump station, the elevation <strong>of</strong> the station, and some characteristic data about thepumps within the station. The table also includes the type <strong>of</strong> control system used at the pumpstation. Local automatic control indicates that the pumps turn on and <strong>of</strong>f in response to apressure sensor at the station or in the system near the station. Telemetry control indicates thaton and <strong>of</strong>f switching is done at the <strong>Bellevue</strong> Service Center. The status report indicates whetherthere is feedback to the operations <strong>of</strong>fice indicating that a pump is on, <strong>of</strong>f, ready to come on, orthat some failure is occurring.StorageStorage facilities are located throughout <strong>Bellevue</strong>’s water system. The storage provides anequalizing effect to meet varying system demands throughout the day, water to meet firedemands, and water for emergencies caused by supply outage or contingency. All <strong>of</strong> <strong>Bellevue</strong>’swater storage facilities are all covered, ground-level reservoirs or standpipes.Table 6-6 lists the storage facilities within the <strong>Bellevue</strong> water system. The table indicates thevolume <strong>of</strong> storage in million gallons (MG) and the maximum and minimum water levels foreach reservoir within the system. Also shown are the primary zones to which each reservoirsupplies water. The <strong>City</strong> continuously records the water level <strong>of</strong> each reservoir at the wateroperations control center.6-16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!