NHXMHHalogen free installation cableStandard: DIN VDE 0250 part 214Nominal voltage: 300/500 VTest voltage: 2000 VCONSTRUCTIONConductor: wire or rope with soft heated copper class 1 or 2 inaccordance with DIN VDE 0295.Insulation: halogen free cross-linked compound.Core: two or more cores are stranded together.Filler: extruded halogen free layer over stranded wires.Sheath: thermoplastic halogen free layer.Sheath colour light gray, RAL 7035.APPLICATIONFor installation for permanent laying in dry and wet spaces over,on, in and under plaster. The direct laying into vibrant and overstressed plaster is not permissible. It can be placed in free space,if protected from direct solar radiation. It cannot be placed to theland and water.Characteristics of the cable in case of fire:- do not spread flame,- combustion elements do not contain halogen elements,- has a low density of smoke in the process of fire.CONSTRUCTION DATA148nxq Cu number Diameter Mass nxq Cu number Diameter Mass[mm 2 ] [kg/km] [mm] [kg/km] [mm 2 ] [kg/km] [mm] [kg/km]1x1,5 15 5,5 40 4 x1,5 58 10,1 1451 x2,5 24 5,9 53 4 x2,5 96 11,2 1991 x4 38 6,7 73 4 x4 154 13,4 2991 x6 58 7,2 96 4 x6 230 15,3 4151 x10 96 8,4 144 4 x10 384 17,7 6361 x16 154 10,0 214 4 x16 614 21,6 9572 x1,5 29 9,0 105 4 x25 960 27,0 14882 x2,5 48 9,9 138 4 x35 1344 30,3 19752 x4 77 11,4 193 5 x1,5 72 10,9 1692 x6 115 12,5 252 5 x2,5 120 12,1 2342 x10 192 15,7 406 5 x4 192 15,0 3693 x1,5 43 9,4 123 5 x6 288 16,5 4933 x2,5 72 10,4 166 5 x10 480 19,0 7493 x4 115 12,0 235 5 x16 768 24,3 11853 x6 173 13,7 325 5 x25 1200 29,7 18053 x10 288 16,1 507 7 x1,5 100 11,7 2063 x16 460 19,6 761 7 x2,5 168 13,5 303n – number of the elemetns, q – nominal cross section of the conductorPermissible conductor temperature:- operating temperature, max +90°C,- in short circuit (max 5 s), max +250°C.Permissible envirement temperature:- for fix laying cables, –30°C to +70°C,- for movable cables, –5°C to +60°C.Smallest bending radius: 12D (D – cable diameter).
N2XHHalogen free cables with improved characteristics in case of fireStandard: DIN VDE 0276Nominal voltage U 0 /U: 0,6/1 kVTest voltage:4 kVCONSTRUCTIONConductor: copper conductor class 1 or class 2 accordingto DIN VDE 0295Insulation: cross-linked polyethylene (XLPE)Core: for multi-core cable cores are stranded together.Filler: halogen free material, fire retardantSheath: thermoplastic halogen free layer.Sheath colour blackAPPLICATIONFor permanent laying in dry and wet areas over, on, in and underplaster. They are laid in pipes in land or in free air. They areintended for buildings where large numbers of people residing and/ or are value equipment, such as industrial plants, hotels,airports, department stores, hospitals, cinemas, ...CONSTRUCTION DATAnxq[mm 2 ]Cu[kg/km]Diamet.[mm]Mass[kg/km]nxq[mm 2 ]Cu[kg/km]Diamet.[mm]Mass[kg/km]nxq[mm 2 ]Cu[kg/km]Diamet.[mm]Mass[kg/km]1x4 39 6,5 71 3x4 116 13,5 287 4x150 5760 46,0 65271x6 58 7,0 91 3x6 173 16,0 420 4x185 7104 50,5 79491x10 96 8,0 151 3x10 288 18,0 600 4x240 9216 53,5 98941x16 154 9,0 205 3x16 461 18,5 765 5x1,5 72 12,0 2061x25 240 10,5 302 3x25 720 24,5 1300 5x2,5 120 13,0 2681x35 336 12,0 404 3x35 1008 24,5 1366 5x4 192 14,0 3641x50 480 13,5 556 3x50 1440 27,0 1800 5x6 288 15,5 4861x70 672 16,0 765 3x70/35 2352 33,0 3000 5x10 480 18,0 7231x95 912 17,0 1006 3x95/50 3216 37,5 4000 5x16 768 22,0 11291x120 1152 18,5 1254 3x120/70 4128 41,0 5100 5x25 1200 26,5 17271x150 1440 21,0 1578 3x150/70 4992 46,5 6100 7x1,5 101 12,5 2451x185 1776 23,0 1925 4x1,5 58 11,0 174 7x2,5 168 14,0 3331x240 2304 26,0 2466 4x2,5 96 11,5 208 12x1,5 173 16,5 3861x300 2880 33,0 3500 4x4 154 14,0 302 12x2,5 288 21,0 5632x1,5 29 9,5 132 4x6 231 14,5 365 14x1,5 202 17,5 4562x2,5 48 10,5 161 4x10 384 16,5 628 14x2,5 336 22,0 6402x4 77 14,5 280 4x16 615 21,0 972 19x1,5 274 18,5 5302x6 116 15,5 350 4x25 960 24,0 1309 19x2,5 456 24,0 8072x10 192 17,0 480 4x35 1344 26,5 1802 24x1,5 346 21,5 6982x16 307 19,5 650 4x50 1920 27,5 2213 24x2,5 576 27,0 9952x25 480 23,5 1000 4x70 2688 32,5 3096 30x1,5 432 23,5 8043x1,5 44 10,0 149 4x95 3648 35,5 4037 30x2,5 720 28,5 11903x2,5 72 11,0 196 4x120 4608 40,0 5115 40x2,5 576 25,5 1017n – number of the elements, q – nominal cross section of the conductorPermissible conductor temperature:operating temperature, max +90°C; in short circuit (max 5 s), max +250°C.Permissible envirement temperature:at laying and handling, min -5°C.Smallest bending radius:for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).149
- Page 1 and 2:
CABLES ANDWIRESNovi Sad, Republic o
- Page 3 and 4:
ContentPOWER CABLES................
- Page 5 and 6:
Company ProfileAbout usThe Cable Fa
- Page 7 and 8:
[Type text]PP 00, PP 00-AВВГ, А
- Page 9 and 10:
PP 40, PP 40-AВВГЭ, АВВГЭ;
- Page 13 and 14:
PP 44; PP 44-ANYRGY, NAYRGYPower ca
- Page 17 and 18:
XP 00, XP 00-AN2XY, NA2XYPower cabl
- Page 19 and 20:
XP 41, XP 41-AПвБбШв, АПв
- Page 21 and 22:
XP 44; XP 44-AN2XRGY, NA2XRGYPower
- Page 23 and 24:
XP 45, XP 45-AN2XFGY, NA2XFGYPower
- Page 25 and 26:
PHP 48, PHP 48-AВВГЭ, АВВГ
- Page 27 and 28:
PHP 81, PHP 81-ANYSEYBY, NAYSEYBYMe
- Page 29 and 30:
PHP 85, PHP 85-ANYSEYFGY, NAYSEYFGY
- Page 31 and 32:
XHP 48, XHP 48-AN2XSEY, NA2XSEYMedi
- Page 33 and 34:
XHEh 91, XHEh 91-AMedium voltage ca
- Page 35 and 36:
XHP 84, XHP 84-AN2XSYRGY, NA2XSYRGY
- Page 37 and 38:
0033
- Page 39 and 40:
PH07V-U, H07V-RInstallation cable w
- Page 41 and 42:
PP/RInstallation cable with PVCStan
- Page 43 and 44:
P/FH07V-KFlexible installation cabl
- Page 45 and 46:
PP/LH03VV-FFlexible cable with PVCS
- Page 47 and 48:
PP/JZFlexible cable with electrical
- Page 49 and 50:
045
- Page 51 and 52:
PP 00NYYSignal cable with PVCStanda
- Page 53 and 54:
PP 44NYRGYSignal cable with PVCStan
- Page 55 and 56:
XP 00N2XYSignal cable with XLPE ins
- Page 57 and 58:
NYSLYCYFlexible signal cable with e
- Page 59 and 60:
NYSLYCYÖH05VVC4V5-K, NSKKE/FFlexib
- Page 61 and 62:
SPZRailway station signal safety ca
- Page 63 and 64:
H01N2-D; ZN/SFlexible welding cable
- Page 65 and 66:
H05RN-FFlexible rubber cableStandar
- Page 67 and 68:
NFK TESFlexible cable for submersib
- Page 69 and 70:
NSGAöu, NSGAFöuRailway cables wit
- Page 71 and 72:
ППСРВМRailway cable with rubb
- Page 73 and 74:
NGFLGöuFlat rubber cableStandard:
- Page 75 and 76:
NFK EpTN, NSHTöuEspecially flexibl
- Page 77 and 78:
NFK SiSi/JFlexible cable for higher
- Page 79 and 80:
NFK EpN 50Flexible mining cable wit
- Page 81 and 82:
EpN 53NSSHöu .../3EFlexible low vo
- Page 83 and 84:
EpN 58Very flexible low voltage min
- Page 85 and 86:
EpN 61 NSSHCGEöu .../3Flexible low
- Page 87 and 88:
EpN 63NSSHCGEöu .../KON+St+ϋlFlex
- Page 89 and 90:
EpN 65NTSCGECWöu ... KONFlexible m
- Page 91 and 92:
EpN 78 NTSCGEWöu ... /3Flexible me
- Page 93 and 94:
MGGPower shipboard cableStandard: D
- Page 95 and 96:
TK59 DSL (30)... M, TK59 DSL (30)..
- Page 97 and 98:
2YYLeading insulated conductorStand
- Page 99 and 100:
J-Y(St)Y ...Installation cableStand
- Page 101 and 102: TI 20Telephone installation cableSt
- Page 103 and 104: TC44 ... E, TC44 ... GESwitchboard
- Page 105 and 106: TZ44 ... E, TZ44 ... GELow-frequenc
- Page 107 and 108: TK33 USelf-supporting low-frequency
- Page 109 and 110: TK59...M, TK59...GMFilled low-frequ
- Page 111 and 112: TK59...MR , TK59...GMRFilled low-fr
- Page 113 and 114: TPP EPLow-frequency telephone subsc
- Page 115 and 116: A-2Y(L)2Y ...St III BdLow-frequency
- Page 117 and 118: TD 39 U-P, TD 59 U-PSelf-supporting
- Page 119 and 120: ТБТЗБLow-frequency subscriber
- Page 121 and 122: S-YYSignal cableStandard: VDE 0813C
- Page 123 and 124: TO SM O3 nxIIx0,4x3,5xCMANOptical c
- Page 125 and 126: 121
- Page 127 and 128: YInstallation insulated conductorSt
- Page 129 and 130: 6YEquipment wire FEP insulatedStand
- Page 131 and 132: LiY; LifY;LiY-T;LifY-TFlexible inte
- Page 133 and 134: Li7YFlexible ETFE insulated conduct
- Page 135 and 136: LiYCY; So-LiYCYCables for electroni
- Page 137 and 138: 133
- Page 139 and 140: NAUK 001,002,003Cables for internal
- Page 141 and 142: NAUK 102Flexible microphone star qu
- Page 143 and 144: NAUK 300Cables for speaker-phonesSt
- Page 145 and 146: NAUK 901, 904Cables for loudspeaker
- Page 147 and 148: LiHHHalogen free cable for electron
- Page 149 and 150: H05ZHalogen free cablesStandard: DI
- Page 151: H07ZZ-FHalogen free flame retardant
- Page 155 and 156: N2XSHMedium voltage halogen free ca
- Page 157 and 158: NHXHXHalogen free cable with improv
- Page 159 and 160: NHXCHXHalogen free cable with elect
- Page 161 and 162: LiHXHXFlexible halogen free cableSt
- Page 163 and 164: LiHXCHXFlexible halogen free cable
- Page 165 and 166: ILAN 120 (ohm) HHalogen free instal
- Page 167 and 168: J-2Y(St)HHalogen free cable for tra
- Page 169 and 170: conductor 0,4 [mm]conductor 0,6 [mm
- Page 171 and 172: THITelephone halogen free installat
- Page 173 and 174: THNJ-HHHalogen free installation ca
- Page 175 and 176: THNE FE 20JE-H(St)H FE20Halogen fre
- Page 177 and 178: MGHHalogen free power shipboard cab
- Page 179 and 180: 175
- Page 181 and 182: RG 50 ΩCoaxial cablesStandard: MIL
- Page 183 and 184: 179
- Page 185 and 186: ALUMOVELD CONDUCTORSAlumoveld condu
- Page 187 and 188: ALUMINIUM CONDUCTORSAluminium condu
- Page 189 and 190: CrosssectionNumber x diameter wirea
- Page 191 and 192: PROTECTIVE ROPES FOR TRANSMISSION L
- Page 193 and 194: X00/AInsulated overhead lineStandar
- Page 195 and 196: СИП 3Insulated overhead lineStan
- Page 197 and 198: 193
- Page 199 and 200: WIRE OF ALUMINIUMRound wire for dif
- Page 201 and 202: TINNED COPPER WIRERound tinned copp
- Page 203 and 204:
COPPER CONDUCTORSStranded copper an
- Page 205 and 206:
BRAIDED COPPER ROPESRound flexible
- Page 207 and 208:
FLAT BRAIDSStranded flat copper and
- Page 209 and 210:
WIRE FOR EROSIMATEBrass wire with a
- Page 211 and 212:
207
- Page 213 and 214:
Properties of materials used for ca
- Page 215 and 216:
Halogen free fire retardant cables
- Page 217 and 218:
[Type text]Conductor resistanceTabl
- Page 219 and 220:
Core markingThe cores of power cabl
- Page 221 and 222:
Number of pairs Core A Core B15 37
- Page 223 and 224:
CURRENT LOADCurrent load of insulat
- Page 225 and 226:
Permitted operatingtemperatureRecom
- Page 227 and 228:
Table: Cables with PVC insulation,
- Page 229 and 230:
Permitted operatingtemperatureEnvir
- Page 231 and 232:
Table: Cables laid in the air, Alum
- Page 233 and 234:
- for three-core cablesNominalcross
- Page 235 and 236:
Permitted short-circuit for electri
- Page 237 and 238:
Table: Single-core cables laid in t
- Page 239 and 240:
[Type text]Transport reelsSizes of
- Page 241 and 242:
[Type text]Length of cable and insu
- Page 243 and 244:
Tests of cables after layingTesting
- Page 245 and 246:
CertificateH03VV-FH03VVH2-FH05VV-FH