КПСРМRailway cable with rubber insulation and sheathStandard: PSNNominal voltage:Test voltage:660V3 kVCONSTRUCTIONConductor: copper conductor class 5.Separator: suitable tape.Insulation: based on EPR rubber, number stamped wire.Sheath: based on polychloroprene rubber, oil, fat and fuelresistant; flame retardant.Sheath colour black.APPLICATIONCable is used in electrical vehicles for current circuits, for currentcircuits for heating and control, as well as for lighting.CONSTRUCTION DATAnxq Cu number Diameter Mass nxq Cu number Diameter Mass[mm 2 ] [kg/km] [mm] [kg/km] [mm 2 ] [kg/km] [mm] [kg/km]7x1,5 101 6,8 324 7x2,5 168 19 45106610x1,5 144 7,3 463 10x2,5 240 22 66212x1,5 173 8,8 514 12x2,5 288 24 71714x1,5 202 10,3 577 14x2,5 336 24 81716x1,5 231 7,4 648 16x2,5 384 27 96519x1,5 274 7,7 747 19x2,5 456 29 109524x1,5 346 9,3 989 30x2,5 720 35 145637x1,5 533 11,0 1462 37x2,5 888 39 2072n – number of the cores; q – nominal cross section conductorPermissible conductor temperature:- operating temperature, max +90°C,- in short circuit (max 5 s), max +250°C.Permissible environment temperature:- at laying, min -20°C,- in use, min -45°C.Smallest bending radius: 4D (D - cable diameter).
ППСРВМRailway cable with rubber insulation and sheathStandard: PSNNominal voltage: 1500V 3000V 4000VTest voltage: 6 kV 12 kV 16 kVCONSTRUCTIONConductor: copper conductor class 5.Separator: suitable tape.Insulation: based on EPR rubber.Sheath: based on polychloroprene rubber, oil, fat and fuelresistant; flame retardant.Sheath colour black.APPLICATIONCable is used in electrical vehicles for current circuits, for currentcircuits for heating and control, as well as for lighting.CONSTRUCTION DATAq Cu number1500V 3000V 4000VDiameter Mass Diameter Mass Diameter Mass[mm 2 ] [kg/km] [mm] [kg/km] [mm] [kg/km] [mm] [kg/km]1,5 15 7,7 65 8,6 87 11,6 1492,5 24 8,5 80 9,1 97 12,1 1634 39 8,8 101 10,6 126 13,6 1956 58 10,6 142 11,7 165 14,5 23810 96 12,4 201 13,3 227 15,7 31316 154 14,5 295 15,1 315 17,9 40525 240 16,4 410 17,6 446 19,4 53435 336 19,0 560 20,2 597 21,0 71150 480 21,0 725 21,4 775 23,2 88570 672 22,0 980 23,2 1030 26,0 117095 912 24,4 1255 25,8 1335 26,6 1440120 1152 27,5 1555 27,9 1626 29,7 1725150 1440 30,9 1885 29,9 1955 32,9 2100185 1776 31,5 2295 32,9 2357 34,1 2455240 2304 36,1 2925 36,7 2978 37,9 2990067q – nominal cross section conductorPermissible conductor temperature:- operating temperature, max +90°C,- in short circuit (max 5 s), max +250°C.Permissible environment temperature:- at laying, min -20°C,- in use, min -45°C.Smallest bending radius: 4D (D - cable diameter).
- Page 1 and 2:
CABLES ANDWIRESNovi Sad, Republic o
- Page 3 and 4:
ContentPOWER CABLES................
- Page 5 and 6:
Company ProfileAbout usThe Cable Fa
- Page 7 and 8:
[Type text]PP 00, PP 00-AВВГ, А
- Page 9 and 10:
PP 40, PP 40-AВВГЭ, АВВГЭ;
- Page 13 and 14:
PP 44; PP 44-ANYRGY, NAYRGYPower ca
- Page 17 and 18:
XP 00, XP 00-AN2XY, NA2XYPower cabl
- Page 19 and 20: XP 41, XP 41-AПвБбШв, АПв
- Page 21 and 22: XP 44; XP 44-AN2XRGY, NA2XRGYPower
- Page 23 and 24: XP 45, XP 45-AN2XFGY, NA2XFGYPower
- Page 25 and 26: PHP 48, PHP 48-AВВГЭ, АВВГ
- Page 27 and 28: PHP 81, PHP 81-ANYSEYBY, NAYSEYBYMe
- Page 29 and 30: PHP 85, PHP 85-ANYSEYFGY, NAYSEYFGY
- Page 31 and 32: XHP 48, XHP 48-AN2XSEY, NA2XSEYMedi
- Page 33 and 34: XHEh 91, XHEh 91-AMedium voltage ca
- Page 35 and 36: XHP 84, XHP 84-AN2XSYRGY, NA2XSYRGY
- Page 37 and 38: 0033
- Page 39 and 40: PH07V-U, H07V-RInstallation cable w
- Page 41 and 42: PP/RInstallation cable with PVCStan
- Page 43 and 44: P/FH07V-KFlexible installation cabl
- Page 45 and 46: PP/LH03VV-FFlexible cable with PVCS
- Page 47 and 48: PP/JZFlexible cable with electrical
- Page 49 and 50: 045
- Page 51 and 52: PP 00NYYSignal cable with PVCStanda
- Page 53 and 54: PP 44NYRGYSignal cable with PVCStan
- Page 55 and 56: XP 00N2XYSignal cable with XLPE ins
- Page 57 and 58: NYSLYCYFlexible signal cable with e
- Page 59 and 60: NYSLYCYÖH05VVC4V5-K, NSKKE/FFlexib
- Page 61 and 62: SPZRailway station signal safety ca
- Page 63 and 64: H01N2-D; ZN/SFlexible welding cable
- Page 65 and 66: H05RN-FFlexible rubber cableStandar
- Page 67 and 68: NFK TESFlexible cable for submersib
- Page 69: NSGAöu, NSGAFöuRailway cables wit
- Page 73 and 74: NGFLGöuFlat rubber cableStandard:
- Page 75 and 76: NFK EpTN, NSHTöuEspecially flexibl
- Page 77 and 78: NFK SiSi/JFlexible cable for higher
- Page 79 and 80: NFK EpN 50Flexible mining cable wit
- Page 81 and 82: EpN 53NSSHöu .../3EFlexible low vo
- Page 83 and 84: EpN 58Very flexible low voltage min
- Page 85 and 86: EpN 61 NSSHCGEöu .../3Flexible low
- Page 87 and 88: EpN 63NSSHCGEöu .../KON+St+ϋlFlex
- Page 89 and 90: EpN 65NTSCGECWöu ... KONFlexible m
- Page 91 and 92: EpN 78 NTSCGEWöu ... /3Flexible me
- Page 93 and 94: MGGPower shipboard cableStandard: D
- Page 95 and 96: TK59 DSL (30)... M, TK59 DSL (30)..
- Page 97 and 98: 2YYLeading insulated conductorStand
- Page 99 and 100: J-Y(St)Y ...Installation cableStand
- Page 101 and 102: TI 20Telephone installation cableSt
- Page 103 and 104: TC44 ... E, TC44 ... GESwitchboard
- Page 105 and 106: TZ44 ... E, TZ44 ... GELow-frequenc
- Page 107 and 108: TK33 USelf-supporting low-frequency
- Page 109 and 110: TK59...M, TK59...GMFilled low-frequ
- Page 111 and 112: TK59...MR , TK59...GMRFilled low-fr
- Page 113 and 114: TPP EPLow-frequency telephone subsc
- Page 115 and 116: A-2Y(L)2Y ...St III BdLow-frequency
- Page 117 and 118: TD 39 U-P, TD 59 U-PSelf-supporting
- Page 119 and 120: ТБТЗБLow-frequency subscriber
- Page 121 and 122:
S-YYSignal cableStandard: VDE 0813C
- Page 123 and 124:
TO SM O3 nxIIx0,4x3,5xCMANOptical c
- Page 125 and 126:
121
- Page 127 and 128:
YInstallation insulated conductorSt
- Page 129 and 130:
6YEquipment wire FEP insulatedStand
- Page 131 and 132:
LiY; LifY;LiY-T;LifY-TFlexible inte
- Page 133 and 134:
Li7YFlexible ETFE insulated conduct
- Page 135 and 136:
LiYCY; So-LiYCYCables for electroni
- Page 137 and 138:
133
- Page 139 and 140:
NAUK 001,002,003Cables for internal
- Page 141 and 142:
NAUK 102Flexible microphone star qu
- Page 143 and 144:
NAUK 300Cables for speaker-phonesSt
- Page 145 and 146:
NAUK 901, 904Cables for loudspeaker
- Page 147 and 148:
LiHHHalogen free cable for electron
- Page 149 and 150:
H05ZHalogen free cablesStandard: DI
- Page 151 and 152:
H07ZZ-FHalogen free flame retardant
- Page 153 and 154:
N2XHHalogen free cables with improv
- Page 155 and 156:
N2XSHMedium voltage halogen free ca
- Page 157 and 158:
NHXHXHalogen free cable with improv
- Page 159 and 160:
NHXCHXHalogen free cable with elect
- Page 161 and 162:
LiHXHXFlexible halogen free cableSt
- Page 163 and 164:
LiHXCHXFlexible halogen free cable
- Page 165 and 166:
ILAN 120 (ohm) HHalogen free instal
- Page 167 and 168:
J-2Y(St)HHalogen free cable for tra
- Page 169 and 170:
conductor 0,4 [mm]conductor 0,6 [mm
- Page 171 and 172:
THITelephone halogen free installat
- Page 173 and 174:
THNJ-HHHalogen free installation ca
- Page 175 and 176:
THNE FE 20JE-H(St)H FE20Halogen fre
- Page 177 and 178:
MGHHalogen free power shipboard cab
- Page 179 and 180:
175
- Page 181 and 182:
RG 50 ΩCoaxial cablesStandard: MIL
- Page 183 and 184:
179
- Page 185 and 186:
ALUMOVELD CONDUCTORSAlumoveld condu
- Page 187 and 188:
ALUMINIUM CONDUCTORSAluminium condu
- Page 189 and 190:
CrosssectionNumber x diameter wirea
- Page 191 and 192:
PROTECTIVE ROPES FOR TRANSMISSION L
- Page 193 and 194:
X00/AInsulated overhead lineStandar
- Page 195 and 196:
СИП 3Insulated overhead lineStan
- Page 197 and 198:
193
- Page 199 and 200:
WIRE OF ALUMINIUMRound wire for dif
- Page 201 and 202:
TINNED COPPER WIRERound tinned copp
- Page 203 and 204:
COPPER CONDUCTORSStranded copper an
- Page 205 and 206:
BRAIDED COPPER ROPESRound flexible
- Page 207 and 208:
FLAT BRAIDSStranded flat copper and
- Page 209 and 210:
WIRE FOR EROSIMATEBrass wire with a
- Page 211 and 212:
207
- Page 213 and 214:
Properties of materials used for ca
- Page 215 and 216:
Halogen free fire retardant cables
- Page 217 and 218:
[Type text]Conductor resistanceTabl
- Page 219 and 220:
Core markingThe cores of power cabl
- Page 221 and 222:
Number of pairs Core A Core B15 37
- Page 223 and 224:
CURRENT LOADCurrent load of insulat
- Page 225 and 226:
Permitted operatingtemperatureRecom
- Page 227 and 228:
Table: Cables with PVC insulation,
- Page 229 and 230:
Permitted operatingtemperatureEnvir
- Page 231 and 232:
Table: Cables laid in the air, Alum
- Page 233 and 234:
- for three-core cablesNominalcross
- Page 235 and 236:
Permitted short-circuit for electri
- Page 237 and 238:
Table: Single-core cables laid in t
- Page 239 and 240:
[Type text]Transport reelsSizes of
- Page 241 and 242:
[Type text]Length of cable and insu
- Page 243 and 244:
Tests of cables after layingTesting
- Page 245 and 246:
CertificateH03VV-FH03VVH2-FH05VV-FH