12.07.2015 Views

CABLES AND WIRES - Novkabel

CABLES AND WIRES - Novkabel

CABLES AND WIRES - Novkabel

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NHXHX FE 180Halogen free cable with insulation funcionality in case of fireStandard: DIN VDE0266Nominal voltage U 0 /U: 0.6/1 kVTest voltage:4 kVCONSTRUCTIONConductor: copper conductor (DIN VDE 0295 class 1 or class 2)Separator: glass-liscun tape (hardly flammable material)Insulation: halogen free cross-linked compound based onpolyolefin (HXI1, DIN VDE 0266)Filler: halogen free compoundSheath: halogen free cross-linked compound based onpolyolefin, heavy inflammable slow-burning material whichrelease a little smoke (HXM1, DIN VDE 0266).Colour orange.APPLICATIONThese cables are intended for installation in the object where there arerather large requirements for safety of people and property - notspreading the fire, not producing dangerous smoke - it is built in buildingswhere making evacuation is difficult and where is very important toprevent fast spreading of a fire.These cables are particularly suitable for installation which should befunctional in the case of the fire (power supply pumps, equipment toextinguish a fire, ventilators for pulling out of smoke, panic lighting, etc).It can be put in the air on the shelf or in the cement in cable canal.It is allowed to be put in the open air.It is not allowed to be put in the earth or in the water.CONSTRUCTION DATA154nxq Cu number Diameter Mass nxq Cu number Diameter Mass[mm 2 ] [kg/km] [mm] [kg/km] [mm 2 ] [kg/km] [mm] [kg/km]1x25 240,0 13 365 4x4 153,6 18 5001x35 336,0 14 455 4x6 230,6 19 6141x50 480,0 16 641 4x50 1920,0 36 29701x70 672,0 17 858 4x70 2688,0 40 40192x1,5 28,8 14 260 4x95 3648,0 45 52133x1,5 43,2 15 296 5x1,5 72,0 17 4063x2,5 72,0 16 347 5x2,5 120,0 18 4833x4 115,2 17 416 5x4 192,0 19 5953x6 172,8 18 509 5x6 288,0 21 7354x1,5 57,6 16 342 5x10 480,0 23 10104x2,5 96,0 17 404 5x16 768,0 27 1457n – number of the elements, q – nominal cross section of the conductorPermissible conductor temperature:operating temperature, max +90°C; in short circuit (max 5 s), max +250°C.Permissible envirement temperature:at laying and handling, min +5°C.Smallest bending radius:for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!