ŽEpN; BT/HTRailway cables with rubber insulation and sheathStandard: SRPS N.C3.350 for ŽEpNUIC 895 for BT i HTNominal voltage: 750V 1500V 3000VTest voltage: 2 kV 6 kV 12 kVCONSTRUCTIONConductor: copper conductor class 5 and class 6.Separator: suitable tape.Insulation: based on EPR rubber.Sheath: based on chlorosulphonated polyethylene rubber,oil, fat and fuel resistant, flame retardant.Sheath colour black.APPLICATIONCable is used in electrical vehicles for current circuits, for currentcircuits for heating and control, as well as for lighting.CONSTRUCTION DATAConstruction 750V 1500V 3000Vq Cu number Diameter Mass Diameter Mass Diameter Mass[mm 2 ] [kg/km] [mm] [kg/km] [mm] [kg/km] [mm] [kg/km]0641,5 15 5,2 45 7,6 81 9,6 1192,5 24 5,9 60 8,1 95 10,1 1334 39 6,6 81 8,6 116 10,6 1576 58 7,6 112 9,7 150 11,7 19810 96 8,9 171 10,9 217 12,7 26316 154 10,5 245 12,1 285 13,9 33525 240 12,4 360 13,6 396 15,4 45435 336 14,0 480 15,2 517 17,0 58150 480 15,0 645 17,4 705 19,2 77570 672 18,0 890 19,2 930 21,0 101095 912 20,4 1135 21,8 1205 23,6 1290120 1152 22,5 1425 23,9 1496 25,7 1595150 1440 24,9 1755 25,9 1815 27,9 1930185 1776 27,5 2125 28,9 2217 30,1 2295240 2304 30,1 2735 32,7 2928 32,9 2930q – nominal cross section conductorPermissible conductor temperature:- operating temperature, max +90°C,- in short circuit (max 5 s), max +250°C.Permissible environment temperature:- at laying, min -20°C,- in use, min -40°C.Smallest bending radius: 6D (D - cable diameter).
NSGAöu, NSGAFöuRailway cables with rubber insulation and sheathStandard: DIN VDE 0250-602Nominal voltage U 0 /U: 0,6/1 kV 1,8/3 kV 3,6/6 kVTest voltage: 2,5 kV 6 kV 11 kVCONSTRUCTIONConductor: tinned copper conductor class 1 and class 2 forNSGAöu and tinned copper conductor class 5 for NSGAFöu.Separator: suitable tape, for 6 kV semi-conductive tape.Insulation: based on EPR rubber (3GI3).Sheath: based on polychloroprene rubber (5GM3), oil, fatand fuel resistant; flame retardant.Sheath colour black.APPLICATIONCable is used in electrical vehicles for current circuits, for currentcircuits for heating and control, as well as for lighting.CONSTRUCTION DATAConstruction 0,6/1 kV 1,8/3 kV 3,6/6 kVq Cu number Diameter Mass Diameter Mass Diameter Mass[mm 2 ] [kg/km] [mm] [kg/km] [mm] [kg/km] [mm] [kg/km]1,5 15 5,1 38 6,1 57 8,7 972,5 24 5,7 50 6,5 73 9,1 1104 39 6,4 72 7,0 90 9,6 1286 58 7,3 95 7,8 112 10,5 15510 96 8,6 146 9,1 158 11,3 22316 154 9,4 198 10,4 223 13,0 28525 240 11,2 296 12,4 329 14,6 38935 336 13,3 420 14,1 478 16,3 54650 480 15,4 574 15,9 594 18,1 66570 672 17,3 783 17,7 803 19,9 88995 912 19,4 992 20,2 1047 21,6 1125120 1152 21,7 1235 22,5 1293 24,9 1369150 1440 23,6 1570 24,4 1685 26,4 1704185 1776 25,6 1920 26,0 2060 27,6 2150240 2304 30,0 2490 30,2 2520065q – nominal cross section conductorPermissible conductor temperature:- operating temperature, max +90°C,- in short circuit (max 5 s), max +250°C.Permissible environment temperature:- at laying, min -20°C,- in use, min -40°C.Smallest bending radius: 6D (D - cable diameter).
- Page 1 and 2:
CABLES ANDWIRESNovi Sad, Republic o
- Page 3 and 4:
ContentPOWER CABLES................
- Page 5 and 6:
Company ProfileAbout usThe Cable Fa
- Page 7 and 8:
[Type text]PP 00, PP 00-AВВГ, А
- Page 9 and 10:
PP 40, PP 40-AВВГЭ, АВВГЭ;
- Page 13 and 14:
PP 44; PP 44-ANYRGY, NAYRGYPower ca
- Page 17 and 18: XP 00, XP 00-AN2XY, NA2XYPower cabl
- Page 19 and 20: XP 41, XP 41-AПвБбШв, АПв
- Page 21 and 22: XP 44; XP 44-AN2XRGY, NA2XRGYPower
- Page 23 and 24: XP 45, XP 45-AN2XFGY, NA2XFGYPower
- Page 25 and 26: PHP 48, PHP 48-AВВГЭ, АВВГ
- Page 27 and 28: PHP 81, PHP 81-ANYSEYBY, NAYSEYBYMe
- Page 29 and 30: PHP 85, PHP 85-ANYSEYFGY, NAYSEYFGY
- Page 31 and 32: XHP 48, XHP 48-AN2XSEY, NA2XSEYMedi
- Page 33 and 34: XHEh 91, XHEh 91-AMedium voltage ca
- Page 35 and 36: XHP 84, XHP 84-AN2XSYRGY, NA2XSYRGY
- Page 37 and 38: 0033
- Page 39 and 40: PH07V-U, H07V-RInstallation cable w
- Page 41 and 42: PP/RInstallation cable with PVCStan
- Page 43 and 44: P/FH07V-KFlexible installation cabl
- Page 45 and 46: PP/LH03VV-FFlexible cable with PVCS
- Page 47 and 48: PP/JZFlexible cable with electrical
- Page 49 and 50: 045
- Page 51 and 52: PP 00NYYSignal cable with PVCStanda
- Page 53 and 54: PP 44NYRGYSignal cable with PVCStan
- Page 55 and 56: XP 00N2XYSignal cable with XLPE ins
- Page 57 and 58: NYSLYCYFlexible signal cable with e
- Page 59 and 60: NYSLYCYÖH05VVC4V5-K, NSKKE/FFlexib
- Page 61 and 62: SPZRailway station signal safety ca
- Page 63 and 64: H01N2-D; ZN/SFlexible welding cable
- Page 65 and 66: H05RN-FFlexible rubber cableStandar
- Page 67: NFK TESFlexible cable for submersib
- Page 71 and 72: ППСРВМRailway cable with rubb
- Page 73 and 74: NGFLGöuFlat rubber cableStandard:
- Page 75 and 76: NFK EpTN, NSHTöuEspecially flexibl
- Page 77 and 78: NFK SiSi/JFlexible cable for higher
- Page 79 and 80: NFK EpN 50Flexible mining cable wit
- Page 81 and 82: EpN 53NSSHöu .../3EFlexible low vo
- Page 83 and 84: EpN 58Very flexible low voltage min
- Page 85 and 86: EpN 61 NSSHCGEöu .../3Flexible low
- Page 87 and 88: EpN 63NSSHCGEöu .../KON+St+ϋlFlex
- Page 89 and 90: EpN 65NTSCGECWöu ... KONFlexible m
- Page 91 and 92: EpN 78 NTSCGEWöu ... /3Flexible me
- Page 93 and 94: MGGPower shipboard cableStandard: D
- Page 95 and 96: TK59 DSL (30)... M, TK59 DSL (30)..
- Page 97 and 98: 2YYLeading insulated conductorStand
- Page 99 and 100: J-Y(St)Y ...Installation cableStand
- Page 101 and 102: TI 20Telephone installation cableSt
- Page 103 and 104: TC44 ... E, TC44 ... GESwitchboard
- Page 105 and 106: TZ44 ... E, TZ44 ... GELow-frequenc
- Page 107 and 108: TK33 USelf-supporting low-frequency
- Page 109 and 110: TK59...M, TK59...GMFilled low-frequ
- Page 111 and 112: TK59...MR , TK59...GMRFilled low-fr
- Page 113 and 114: TPP EPLow-frequency telephone subsc
- Page 115 and 116: A-2Y(L)2Y ...St III BdLow-frequency
- Page 117 and 118: TD 39 U-P, TD 59 U-PSelf-supporting
- Page 119 and 120:
ТБТЗБLow-frequency subscriber
- Page 121 and 122:
S-YYSignal cableStandard: VDE 0813C
- Page 123 and 124:
TO SM O3 nxIIx0,4x3,5xCMANOptical c
- Page 125 and 126:
121
- Page 127 and 128:
YInstallation insulated conductorSt
- Page 129 and 130:
6YEquipment wire FEP insulatedStand
- Page 131 and 132:
LiY; LifY;LiY-T;LifY-TFlexible inte
- Page 133 and 134:
Li7YFlexible ETFE insulated conduct
- Page 135 and 136:
LiYCY; So-LiYCYCables for electroni
- Page 137 and 138:
133
- Page 139 and 140:
NAUK 001,002,003Cables for internal
- Page 141 and 142:
NAUK 102Flexible microphone star qu
- Page 143 and 144:
NAUK 300Cables for speaker-phonesSt
- Page 145 and 146:
NAUK 901, 904Cables for loudspeaker
- Page 147 and 148:
LiHHHalogen free cable for electron
- Page 149 and 150:
H05ZHalogen free cablesStandard: DI
- Page 151 and 152:
H07ZZ-FHalogen free flame retardant
- Page 153 and 154:
N2XHHalogen free cables with improv
- Page 155 and 156:
N2XSHMedium voltage halogen free ca
- Page 157 and 158:
NHXHXHalogen free cable with improv
- Page 159 and 160:
NHXCHXHalogen free cable with elect
- Page 161 and 162:
LiHXHXFlexible halogen free cableSt
- Page 163 and 164:
LiHXCHXFlexible halogen free cable
- Page 165 and 166:
ILAN 120 (ohm) HHalogen free instal
- Page 167 and 168:
J-2Y(St)HHalogen free cable for tra
- Page 169 and 170:
conductor 0,4 [mm]conductor 0,6 [mm
- Page 171 and 172:
THITelephone halogen free installat
- Page 173 and 174:
THNJ-HHHalogen free installation ca
- Page 175 and 176:
THNE FE 20JE-H(St)H FE20Halogen fre
- Page 177 and 178:
MGHHalogen free power shipboard cab
- Page 179 and 180:
175
- Page 181 and 182:
RG 50 ΩCoaxial cablesStandard: MIL
- Page 183 and 184:
179
- Page 185 and 186:
ALUMOVELD CONDUCTORSAlumoveld condu
- Page 187 and 188:
ALUMINIUM CONDUCTORSAluminium condu
- Page 189 and 190:
CrosssectionNumber x diameter wirea
- Page 191 and 192:
PROTECTIVE ROPES FOR TRANSMISSION L
- Page 193 and 194:
X00/AInsulated overhead lineStandar
- Page 195 and 196:
СИП 3Insulated overhead lineStan
- Page 197 and 198:
193
- Page 199 and 200:
WIRE OF ALUMINIUMRound wire for dif
- Page 201 and 202:
TINNED COPPER WIRERound tinned copp
- Page 203 and 204:
COPPER CONDUCTORSStranded copper an
- Page 205 and 206:
BRAIDED COPPER ROPESRound flexible
- Page 207 and 208:
FLAT BRAIDSStranded flat copper and
- Page 209 and 210:
WIRE FOR EROSIMATEBrass wire with a
- Page 211 and 212:
207
- Page 213 and 214:
Properties of materials used for ca
- Page 215 and 216:
Halogen free fire retardant cables
- Page 217 and 218:
[Type text]Conductor resistanceTabl
- Page 219 and 220:
Core markingThe cores of power cabl
- Page 221 and 222:
Number of pairs Core A Core B15 37
- Page 223 and 224:
CURRENT LOADCurrent load of insulat
- Page 225 and 226:
Permitted operatingtemperatureRecom
- Page 227 and 228:
Table: Cables with PVC insulation,
- Page 229 and 230:
Permitted operatingtemperatureEnvir
- Page 231 and 232:
Table: Cables laid in the air, Alum
- Page 233 and 234:
- for three-core cablesNominalcross
- Page 235 and 236:
Permitted short-circuit for electri
- Page 237 and 238:
Table: Single-core cables laid in t
- Page 239 and 240:
[Type text]Transport reelsSizes of
- Page 241 and 242:
[Type text]Length of cable and insu
- Page 243 and 244:
Tests of cables after layingTesting
- Page 245 and 246:
CertificateH03VV-FH03VVH2-FH05VV-FH