N2XH FE 180Halogen free cable with improved characteristics and insulation function incase of fireStandard: DIN VDE0276Nominal voltage U 0 /U: 0.6/1 kVTest voltage:4 kVCONSTRUCTIONConductor: copper class 1 or class 2 (DIN VDE 0295).Separator: mica tape.Insulation: cross-linked polytehylene (XLPE).Ispuna: halogen free, flame retardant material.Plašt: thermoplastic halogen free flame retardant material.Sheath colour orange.150APPLICATIONCONSTRUCTION DATAHalogen free cables with improved characteristics and isolation functionalityin case of fire:- do not spread fire and flame,- products of the combustion are not corrosive,- low smoke density during combustion.- they can supply power in the fire, minimum 180 minute - FE 180.This type is suitable for high housing and office buildings, department stores,theaters, cinemas, etc. where are a lot of people or value equipment.These cables are intended for installation in the object where there arerather large requirements for safety and where making evacuation is difficultand where is very important to prevent fast spreading of a fire.These cables are particularly suitable for installation which should befunctional in the case of the fire (power supply pumps, equipment toextinguish a fire, ventilators for pulling out of smoke, panic lighting, etc).It can be put in the air on the shelf or in the cement in cable canal.It is allowed to be put in the open air.It is not allowed to be put in the earth or in the water.nxq Cu number Diameter Mass nxq Cu number Diameter Mass[mm 2 ] [kg/km] [mm] [kg/km] [mm 2 ] [kg/km] [mm] [kg/km]1x25 240 13 345 4x4 154 18 4801x35 336 14 445 4x6 231 19 6041x50 480 16 635 4x50 1920 36 28661x70 672 17 848 4x70 2688 40 38992x1,5 29 14 255 4x95 3648 45 51743x1,5 44 15 286 5x1,5 72 17 3963x2,5 72 16 338 5x2,5 120 18 4653x4 116 17 404 5x4 192 19 5813x6 173 18 489 5x6 288 21 7224x1,5 58 16 332 5x10 480 23 9804x2,5 96 17 394 5x16 768 27 1337n – number of the elements, q – nominal cross section of the conductorPermissible conductor temperature:operating temperature, max +90°C; in short circuit (max 5 s), max +250°C.Permissible envirement temperature:at laying and handling, min -5°C.Smallest bending radius:for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!