ППСРМORailway cable with rubber insulation and sheathStandard: PSNNominal voltage: 1500V 3000V 4000VTest voltage: 6 kV 12 kV 16 kVCONSTRUCTIONConductor: copper conductor class 5.Separator: suitable tape.Insulation: based on EPR rubber, number stamped wire.Sheath: based on polychloroprene rubber, oil, fat and fuelresistant; flame retardant.Sheath colour black.APPLICATIONCable is used in electrical vehicles for current circuits, for currentcircuits for heating and control, as well as for lighting.CONSTRUCTION DATAq Cu number1500 V 3000 V 4000 VDiameter Mass Diameter Mass Diameter Mass[mm 2 ] [kg/km] [mm] [kg/km] [mm] [kg/km] [mm] [kg/km]1,0 10 5,2 43 6,2 55 8,6 991,5 15 5,6 52 6,6 66 9,0 1192,5 24 6,5 68 7,1 84 9,8 1330684 39 6,8 85 7,6 96 10,6 1576 58 7,9 112 8,7 136 11,5 19810 96 9,4 171 10,4 197 12,7 263q – nominal cross section conductorPermissible conductor temperature:- operating temperature, max +90°C,- in short circuit (max 5 s), max +250°C.Permissible environment temperature:- at laying, min -20°C,- in use, min -45°C.Smallest bending radius: 4D (D - cable diameter).