12.07.2015 Views

CABLES AND WIRES - Novkabel

CABLES AND WIRES - Novkabel

CABLES AND WIRES - Novkabel

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NHXCHX FE 180Halogen free cabel with protective conductor and inuslation funcionalityStandard: DIN VDE0266Nominal voltage U 0 /U: 0.6/1 kVTest voltage:4 kVCONSTRUCTIONConductor: copper conductor (DIN VDE 0295 class 1 or class 2)Separator: glass-liscun tape (hardly flammable material)Insulation: halogen free cross-linked compound based onpolyolefin (HXI1, DIN VDE 0266)Filler: halogen free compoundConcentric conductor: copper wire with counter spiral madefrom copper tapeSheath: halogen free cross-linked compound, flame retardant,based on polyolefin (HXM1, DIN VDE 0266).Color: orange.APPLICATIONThis cable is intended for installation in high residential and businessbuildings, department stores, theaters, cinemas, etc.. when in case of firesuch facilities is difficult to leave and where fire cannot be spread for min.180 minutes of its emergence. These cables are particularly suitable forinstallation which should be functional in the case of the fire (power supplypumps, equipment to extinguish a fire, ventilators for pulling out ofsmoke, panic lighting, etc).It can be put in the air on the shelf or in the cement in cable canal thatneed to preserve the integrity and stability in terms of fire activity in therequired time for proper installation.CONSTRUCTION DATA156nxq Cu number Diameter Mass nxq Cu number Diameter Mass[mm 2 ] [kg/km] [mm] [kg/km] [mm 2 ] [kg/km] [mm] [kg/km]2x1,5/1,5 52 16 300 4x1,5/1,5 81 18 3802x2,5/2,5 80 17 350 4x2,5/2,5 128 19 4502x4/4 123 18 420 4x4/4 200 20 5502x6/6 182 19 500 4x6/6 297 21 7002x10/10 312 21 700 4x10/10 504 24 10003x1,5/1,5 66 17 320 4x16/16 796 27 14003x2,5/2,5 104 18 380 4x25/16 1142 32 19003x4/4 161 19 480 4x50/25 2203 39 32003x6/6 240 20 600 4x70/35 3082 44 44003x10/10 408 22 850 4x95/50 4208 52 61003x16/16 643 25 1200 7x1,5/2,5 133 20 5003x25/25 1003 29 1700 10x1,5/2,5 176 24 7003x35/35 1402 32 2200 12x1,5/2,5 205 25 7503x50/50 2000 37 2900 7x2,5/2,5 200 22 6503x70/70 2796 42 3900 10x2,5/4 286 26 9003x95/95 3791 47 5200 12x2,5/4 334 27 950n – number of the elements, q – nominal cross section of the conductor, q 1 – nominal cross section of the protectiveconductorPermissible conductor temperature:operating temperature, max +90°C; in short circuit (max 5 s), max +250°C.Permissible envirement temperature:at laying and handling, min +5°C.Smallest bending radius:for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!