12.07.2015 Views

Fusion Programme - ENEA - Fusione

Fusion Programme - ENEA - Fusione

Fusion Programme - ENEA - Fusione

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

9. Medical, Energetic, Environmental Applications2007 Progress ReportFig. 9.2 – a) Bubble detectors in front of the beam; b) bubble detectors inside the polyethylene phantom placed infront of the beamspectrum was then determined by an unfoldingmethod based on the Gravel algorithm. Preliminarymeasurements of the gamma component wereperformed by means of an ionization chamber.All the measurements will undergo further checks andthe results obtained by the different techniques will becompared.In the framework of research into newboron carriers for treating skinmelanoma, the therapeutic effects ofthe HYTHOR radiation field on mousemelanoma (without boron injection)were evaluated as a preliminary part ofa comprehensive study concerning local control of theThe thermalcolumnHYTHOR atTAPIROtumour through the boron neutron capture effect. Several studies were carried out to set up theexperimental procedures. In the irradiation cavity (14×14×24 cm 3 ), up to six mice can be simultaneouslyirradiated. Control mice underwent identical experimental procedures (including anaesthesia, transport toand from the nuclear reactor) to the irradiated mice, but were not exposed to irradiation. The resultsobtained will be compared with future irradiation of mouse melanoma with boron injection. The neutrondose was monitored by using one of the ionisation chambers inserted inside the TAPIRO reactor. Theionisation chamber current was measured with a Keithley 614 electrometer interfaced with a personalcomputer.With regard to the microdosimetry of mixed radiation fields such as BNCT, special mini tissue-equivalentproportional counters (TEPCs) were designed and constructed by INFN Legnano and then tested in theHYTHOR facility [9.3]. The sensitive volume of the proportional counters is about 1 mm 3 . A twin mini-TEPCwas also constructed to obtain the different dosecomponents in a single measurement. This detector is[9.3] Davide Moro, Development of tissue equivalentproportional counters for BNCT microdosimetry,PhD thesis (2007)Fig. 9.3 – One of the Bonner spheres in front of the beamcomposed of two independent mini-TEPCs, onecontaining the boron isotope 10 B (simulating thecancerous region), the other boron free (simulating thehealthy tissue).149

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!