12.07.2015 Views

APPENDIX 2.10-A Format of Tender Notice for ... - Cg.nic.in

APPENDIX 2.10-A Format of Tender Notice for ... - Cg.nic.in

APPENDIX 2.10-A Format of Tender Notice for ... - Cg.nic.in

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Chap. II ]189[ Appendix <strong>2.10</strong> AANNEXURE-HSAFETY CODE1. Scaffold<strong>in</strong>g –(i) Suitable scaffolds should be provided <strong>for</strong> workman <strong>for</strong> allworks that cannot safely be done from the grounds or from solid constructionexcept such short period work as can be done safely from ladders. When aladder is used an extra mazdoor shall be engaged <strong>for</strong> hold<strong>in</strong>g the ladder <strong>for</strong>carry<strong>in</strong>g materials as well as suitable foot holds and hand holds shall beprovided on the ladder and the ladder shall be given an <strong>in</strong>cl<strong>in</strong>ation not steeperthan 1/4:1 (1/4 Horizontal and 1 Vertical).(ii)Scaffold<strong>in</strong>g or stag<strong>in</strong>g more than 3.50m, above the ground floor, swung orsuspended from an overhead support or erected with stationery support shallhave a guard rail properly attached, bolted, braced or otherwise secured atleast 1 metre high above the floor plat<strong>for</strong>ms <strong>of</strong> such scaffold<strong>in</strong>g or stag<strong>in</strong>g andextend<strong>in</strong>g along the entire length <strong>of</strong> the outside the ends there<strong>of</strong> with onlysuch open<strong>in</strong>g as may be necessary <strong>for</strong> the delivery <strong>of</strong> the materials. Suchscaffold<strong>in</strong>g or stag<strong>in</strong>g shall be fastened as to prevent it from sway<strong>in</strong>g from thebuild<strong>in</strong>g <strong>of</strong> structure.(iii)Work<strong>in</strong>g plat<strong>for</strong>m gangways and stairways should be so constructed that theyshould not sway unduly or unequally and if the height <strong>of</strong> the plat<strong>for</strong>m <strong>of</strong> thegangway or the stairway is more than 3.54 metre above ground level and orfloor level they should be closely boarded ,should have adequate width andshould be suitably fenced as described (ii) above.(iv)Every open<strong>in</strong>g <strong>in</strong> the floor <strong>of</strong> a build<strong>in</strong>g or <strong>in</strong> a work<strong>in</strong>g plat<strong>for</strong>m be providedwith suitable means to prevent the fall<strong>in</strong>g <strong>of</strong> persons or materials by provid<strong>in</strong>gsuitable fenc<strong>in</strong>g or rail<strong>in</strong>g whose m<strong>in</strong>imum height shall be 1 metre.(v)Safe means <strong>of</strong> access shall be provided to all work<strong>in</strong>g plat<strong>for</strong>ms and otherwork<strong>in</strong>g places. Every ladder shall be securely fixed . No portable ladder shallbe over 9 metre <strong>in</strong> length while the width between side rails <strong>in</strong> r<strong>in</strong>g laddershall be <strong>in</strong> no case be less than 0.3 metre <strong>for</strong> ladder up to and <strong>in</strong>clud<strong>in</strong>g 3meters length. For longer ladders this width should be <strong>in</strong>creased at least 2 cm.<strong>for</strong> each additional metre <strong>of</strong> length. Uni<strong>for</strong>m step spac<strong>in</strong>g shall not exceed0.3mt. Adequate precaution shall be taken to prevent danger from electricalequipment. No material on any <strong>of</strong> the work site shall be so stacked or placedas to cause danger or <strong>in</strong>convenience to any person or the public. Thecontractor shall also provide all necessary fenc<strong>in</strong>g and lights to protect thepublic from accident and shall be bound to bear the expenses <strong>of</strong> defense <strong>of</strong>every suit action or other precautions <strong>of</strong> law that may be brought by anyperson <strong>for</strong> <strong>in</strong>jury susta<strong>in</strong>ed ow<strong>in</strong>g to neglect <strong>of</strong> the above and to pay any

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!