HISTORIC STRUCTURE REPORTFINALWindowNumberType Condition Comments101 SG/3,C 3, 2, 2MAIN FLOOR102 SG/1, F 2-3 Buckling in center portion of panelThree-light window: left casement, fixed center, right casement. Left casement has significant buckling, needsimmediate repair. Center fixed panel has existing minor repairs in the medallion that should be redone in studio.Right casement has a few broken pieces of glass in the diamond-patterned area and should be either leaded orreplaced. Repair/refinish hardware.103 WF,C,G 2104 WF,C,O 1201 SG/4, A 3Immediate repair of bottom rail and sill – water damage and joint separation. Window sealed shut andinoperable. Corroded hardware. Needs paint.Immediate repair of bottom rail and sill – water damage and joint separation. Reglazing needed. Repair/refinishhistoric hardware. Needs paintCLERESTORYFour-panel window, significant buckling in second from top panel. Window has renderings of PresidentsMcKinley and Roosevelt with mention of Cuba and USA202 SG/4, A 3 Buckling of panels 1 and 4. Window honors Loyalty and Fortitude203 SG/4, A 3 Panel 1 has significant buckling. Window honors American War MothersNone assigned SG/4, F unknownNot visible from the exterior and thus not evaluated by the stained glass conservator. Given its relativelyprotected position within the bell tower, the stained glass is likely in good condition. However, window may beunder stress, because there is a structural settlement crack at the window’s lower right.204 SG/1, F 3Window has geometric pattern, glazed with clear glass located in bell tower. Major water damage: rot, jointseparation, delamination, cracking and efflorescence at frame. Window lead is corroded. Major efflorescence andspalling of surrounding plaster. Window faces imminent failure.205 SG/1, F 3Window has geometric pattern, glazed with clear glass located in bell tower. Major water damage: rot, jointseparation, delamination, cracking and efflorescence at frame. Window lead is corroded. Major efflorescence andspalling of surrounding plaster. Window faces imminent failure.42MARCH 2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!