Pre-Installation ItemsRecommended ClearancesThe PRESTIGE Solo is approved for zeroclearance to combustibles, excluding vent andboiler piping.- Boiler Piping - 1/4 inch from combustiblematerials.- Reference the appropriate vent supplementfor clearance requirements.BEST PRACTICETo provide serviceability to the unit it isrecommended that the following clearancesbe maintained:Top boiler jacket - 24 inches [610 mm].Front - 24 inches [610 mm].Bottom boiler piping - 24 inches[610 mm].Rear - 0 inchesSides - 6 inches [153 mm].WARNINGIf the clearances listed above cannot bemaintained or the enclosed in which theboiler is installed is less than 85 cubic feet,the space must be ventilated. See page 6for ventilation requirements.NOTICEWhen maintaining zero clearance or lessthan recommended clearances, someproduct labeling may become hiddenand unreadable.WARNINGWhen installing the PRESTIGE Solo ina confined space, sufficient air must beprovided for proper combustion andventing and to allow, under normal operatingconditions, proper air flow aroundthe product to maintain ambient temperatureswithin safe limits to comply withthe National Fuel Gas Code NFPA 54 -latest edition.4Residential Garage InstallationsWhen installing the PRESTIGE Solo in a residentialgarage, the following special precautionsper NFPA 54/ANSI Z223.1 must be taken:- Mount the unit with a minimum 18inches [458 mm] above the floor levelof the garage. Ensure the burner andignition devices / controls are no lessthan 18 inches [458 mm] above thefloor level.- Locate or protect the unit in a matterso it cannot be damaged by a movingvehicle.Boiler Freeze Protection FeatureThe boiler control has an freeze protection featurebuilt in. This feature monitors the boilertemperature and responds as follows when nocall for heat is present:- 46ºF Boiler circulator is ON- 38ºF Boiler circulator is ON and burneroperates at low fire- 50ºF Burner OFF and boiler circulatoroperates for approximately 10 minutesCAUTIONThe boiler freeze protection feature isdisabled during a hard lockout, howeverthe CH circulator will operate.CAUTIONThe boiler freeze protection feature isdesigned to protect the boiler. The boilershould be installed in a primary/secondarypiping arrangement if it isinstalled in an unheated space orexposed to water temperatures of 46ºF orless. See Section IV for primary/secondarypiping examples. See Section IXfor antifreeze guidelines

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!