Factory Setting ParametersFactory Setting Parameters1 140ºF DHW Setting2 01 DHW Application Selection3 01 CH Application Selection4 186ºF CH Maximum Boiler Operating Setpoint10 86ºF CH Minimum Boiler Operating Setpoint11 00ºF CH Reset Curve Coldest Day12 64ºF CH Reset Curve Warmest Day13 -22ºF Frost Protection Setpoint18 32ºF CH Block Temperature Setting19 00 Minutes Boost Feature Setting20 00ºF Parallel Shift Value21 46ºF Setpoint Value Addition for DHW32 01 Minutes CH Circulator Post Pump Time Period33 03 x 10.2 Sec. DHW Circulator Post Pump Time Period38 02ºF DHW On Differential39 06ºF DHW Off Differential40 03 x 10.2 Sec. CH Call Blocking Time41 00 x 10.2 Sec. DHW Call Blocking Time42 00 x 10.2 Sec. DHW to CH Call Blocking Time43 00 Minutes DHW Priority Timeout45 00 CH Operating Signal Selection46 02 DHW Operating Signal Selection55