13.07.2015 Views

Prestige SOLO 110.pdf - Bloom Lake Farms

Prestige SOLO 110.pdf - Bloom Lake Farms

Prestige SOLO 110.pdf - Bloom Lake Farms

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Pre-Installation ItemsSECTION I - Pre-Installation ItemsCode ComplianceThis product must be installed in accordance tothe following:- All applicable local, state, national andprovincial codes, ordinances, regulationsand laws.- For installations in Massachusetts -code requires the boiler to be installedby a licensed plumber or gas fitter, andif antifreeze is utilized, the installationof a reduced pressure backflow preventerdevice is required in the boiler’s coldwater fill or make up water supply line.- For installation in Massachusetts alldirect vented appliances must complywith the guidelines as outlined onpage 11.- The National Fuel Gas Code NFPA54/ANSI Z 223.1 - Latest edition.- National Electric Code ANSI/NFPA 70.- For installations in Canada -“InstallationCode for Gas Burning Equipment”CGA/B149.1 or B149.2 CanadianElectrical Code Part 1 CSA C22.1.- Standards for Controls and SafetyDevices for Automatically Fired Boilers,ANSI/ASME CSD-1, when required.NOTICEThe PRESTIGE Solo boiler gas manifoldand gas controls meet the safe lightingand other performance requirements asspecified in ANSI Z21.13 latest edition.Determining Product LocationBefore locating the PRESTIGE Solo check forconvenient locations to:- Heating system piping- Venting- Gas supply piping- Electrical serviceEnsure the boiler location allows the combustionair/vent piping to be routed directly throughthe building and terminate properly outside witha minimum amount of length and bends.Ensure the area chosen for the installation of thePRESTIGE Solo is free of any combustiblematerials, gasoline and other flammable liquids.WARNINGFailure to remove or maintain the areafree of combustible materials, gasolineand other flammable liquids or vaporscan result in severe personal injury,death or substantial property damage.Ensure the PRESTIGE Solo and its controls areprotected from dripping or spraying water duringnormal operation or service.The PRESTIGE Solo should be installed in alocation so that any water leaking from theboiler or piping connections or relief valve willnot cause damage to the area surrounding theunit or any lower floors in the structure.Boiler ReplacementIf the PRESTIGE Solo is replacing an existingboiler, the following items should be checkedand corrected prior to installation:- Boiler piping leaks and corrosion.- Improper location and sizing of theexpansion tank on the boiler heatingloop.- If applicable, level and quality of freezeprotection within the boiler system.3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!