Start-Up ProceduresSet Boiler CH Target Temperature1. Press the MODE button until the displayshows PARA. This is the Parameter modeof the control.2. Press the STEP button until the first digiton the display shows "4". The last threedigits on the display shows the outlet watertemperature setting (high limit).3. Press the "+" or "-" button to change thesetting of the outlet temperature (highlimit).NOTICEIf an outdoor sensor is used, then the settingof the Boiler CH Target temperatureis the target temperature when the outdoortemperature is at or below 0ºF.When the outdoor temperature is higherthan 0ºF the PRESTIGE Solo control willcalculate the target temperature betweenthe minimum and maximum temperaturesettings.4. Press the "STORE" button to save the setting.Operation Verification - Space HeatingNOTICEDigits and characters shown as [0000],in the following outline, represent thecontrol panel display. The last three digitson the display is the measured boilerwater temperature and may differ fromwhat is shown in the manual.1. Disconnect the DHW (Domestic HotWater) thermostat wiring from the PRES-TIGE Solo or turn down DHW tank aquastat(if used) to ensure the boiler does notreceive a DHW call for heat.2. Set the room thermostat to the lowest setting.3. Turn off power to the boiler, wait a fewseconds and turn on power to the boiler.4. The following displays should occur:[U1.22] Software Version[A140] Self check on power up[0140] No call for heat5. Initiate a call for heat by raising the setpoint of the room thermostat to the highestsetting. The following display shouldoccur.[5140] This is a fan / air flow check. Theburner blower will be energized momentarilyprior to the prepurge cycle.[1140] This is the prepurge cycle. Theboiler blower and the CH (Central Heating)circulator become energized. The blowerhas a 10 second prepurge cycle.[2140] This is the ignition cycle. The controlmodule will energize and open the gasvalve and begin the spark for ignition.- If the burner flame proves the burnerwill continue to fire at an ignition fanspeed for approximately 10 seconds tostabilize the flame.- If the burner flame is not proven thecontrol module will repeat the ignitionsequence. If the flame is not provenafter 5 attempts the control will lockoutand the display will show [E-02]- To verify flame failure lockout, closethe manual shut off valve on the gassupply piping to the boiler and repeatignition sequence. When verification iscompleted, ensure the manual shut offvalve is returned to the open position.[3140] This is the normal operation cycle.After the flame is proven and stabilizedthe burner will fire at low input forapproximately 1 minute. After this timeperiod, the control module will begin tomodulate the burner firing rate based onactual boiler outlet temperature and the setpoint temperature.43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!