Combustion Air and VentingVentilation and Combustion AirRequirements - Direct VentA Direct Vent appliance utilizes uncontaminedoutdoor air (piped directly to the appliance) forcombustion)For Direct Vent installations, involving onlythe PRESTIGE Solo, in which the minimumservice clearances are maintained as listed onpage 4, no ventilation openings are required.For Direct Vent, zero clearance installationsinvolving only the PRESTIGE Solo, the space/ enclosure must provide two openings for ventilation.The openings must be sized to provide1 square inch of free area per 1,000 BTUH ofboiler input. The openings shall be placed 12inches from the top of the space and 12 inchesfrom the floor of the space.For installations in which the PRESTIGE Soloshares the space with air movers (exhaust fan,clothes dryers, fireplaces, etc.) and other combustionequipment (gas or oil) the space mustbe provided with adequate air openings to provideventilation and combustion air to theequipment. To properly size the ventilation /combustion air openings, the installer mustcomply with the National Fuel Gas CodeNFPA 54, ANSI Z223.1 for installations in theU.S or CSA B149.1 and B149.2 for installationsin Canada.WARNINGThe space must be provided with ventilation/ combustion air openings properlysized for all make-up air requirements(exhaust fans, clothes dryers, fireplaces,etc.) and the total input of all applianceslocated in the same space as the PRES-TIGE Solo, excluding the input of aDirect Vent PRESTIGE Solo which usescombustion air directly from the outside,thus additional free area for the openingsis not required. Failure to provideor properly size the openings couldresult in severe personal injury, death orsubstantial property damage.Ventilation and Combustion AirRequirements - Category IVA Category IV appliance utilizes uncontaminatedindoor or outdoor air (surrounding theappliance) for combustion.BEST PRACTICEIn order to reduce the potential risksassociated with indoor contaminates(listed on page 5), flammable vapors andtight housing construction (little or noinfiltration air), it is recommended topipe uncontaminated combustion airdirectly from the outdoors to the appliance.This practice also promotes highersystem efficiency by reducing heatedindoor air from being exhausted fromthe house and replaced by cold infiltrationair into the house.For installations in which the PRESTIGE Soloshares the space with air movers (exhaust fan,clothes dryers, fireplaces, etc.) and other combustionequipment (gas or oil) the space must beprovided with adequate air openings to provideventilation and combustion air to the equipment.To properly size the ventilation / combustion airopenings, the installer must comply with theNational Fuel Gas Code NFPA 54, ANSI Z223.1for installations in the U.S or CSA B149.1 andB149.2 for installations in Canada, as referencedin this section of the manual and titled Methodsof Accessing Combustion Air into a Space.WARNINGThe space must be provided with ventilation/ combustion air openings properlysized for all make-up air requirements(exhaust fans, clothes dryers, fireplaces,etc.) and the total input of all appliancesincluding the PRESTIGE Solo whenlocated in the same space. Failure to provideor properly size the openings couldresult in severe personal injury, death orsubstantial property damage.6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!