13.07.2015 Views

Technical Appendix Specifications for the RADIO SYSTEM UPGRADE

Technical Appendix Specifications for the RADIO SYSTEM UPGRADE

Technical Appendix Specifications for the RADIO SYSTEM UPGRADE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Terminating Cross ConnectA. To conserve space in <strong>the</strong> wall mounted cross connect backboard small "110" or 3 M "BICS"type blocks should be utilized.B. The preferred terminating/cross connect type equipment is <strong>the</strong> KRONE, INC. LSA-PLUSseries of blocks.C. All terminations must be clearly marked and labeled to allow rapid identification of everycircuit and its termination point to facilitate repair or relocation of equipment.D. To <strong>the</strong> greatest extent possible, all equipment intercabling and/or cable/wiring bundles shallbe neatly secured by means of plastic tie wraps, secured by surface mounted clamps andhidden from view.ReferencesWithout limiting <strong>the</strong> generality of o<strong>the</strong>r requirements of this Specification, all work specifiedherein shall con<strong>for</strong>m to or exceed <strong>the</strong> applicable requirements of <strong>the</strong> referenced Standards;provided that wherever <strong>the</strong> provisions of listed publications are in conflict with <strong>the</strong> requirementsspecified herein, <strong>the</strong> more stringent requirements shall apply unless in conflict with <strong>the</strong> equipmentmanufacturer’s written recommendations: Title 24 of <strong>the</strong> Cali<strong>for</strong>nia Code of Regulations (CCR; Effective November 1, 2002),which includes:Part 1 - Cali<strong>for</strong>nia Building Standards Administrative CodePart 2 - Cali<strong>for</strong>nia Building Code (Volumes 1, 2 and 3)Part 3 - Cali<strong>for</strong>nia Electrical Code (effective August 1, 2005)Part 6 - Cali<strong>for</strong>nia Energy Code (effective October 1, 2005).Part 9 - Cali<strong>for</strong>nia Fire CodePart 12 - Cali<strong>for</strong>nia Reference Standards CodeCali<strong>for</strong>nia Essential Services Building Act, Health and Safety Code Chapter 2, Section16000 (includes, but is not limited to nonstructural components such as communicationssystems, power switching equipment, and emergency backup systems) NEC 70 (National Electrical Code) Sections 100-300 and Section 800All pertinent FCC rules and regulations, specifically including 47 CFR Part 90: PrivateLand Mobile Radio; Part 15, Subpart J: Computing Devices; and Part 2, Subpart J, FCCEquipment Authorization Procedures.47 CFR 1.1310 – Radio Frequency Radiation Exposure LimitsProject 25 System & Standard Definitions (TSB102A), and all referenced designdocuments (TSB [Telecommunications Systems Bulletin], IS- [Interim Standard] or TIA[Telecommunication Industry Association Standard]).Uni<strong>for</strong>m Building Code, including <strong>the</strong> seismic requirements of Section 2312, <strong>for</strong>Earthquake Zone 4ANSI/TIA/EIA Standards RS 232-C, RS 485, Category 5/5e/6 ANSI/TIA/EIA-568-A/BCity of San Luis Obispo 81 Radio System Upgrade TECHNICAL APPENDIX

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!