13.07.2015 Views

Technische fiche - Delta-Temp

Technische fiche - Delta-Temp

Technische fiche - Delta-Temp

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BT08L005GB-01362402452464524604704804904PACKAGED362 - 904PERFORMANCES OF SUPPLY AIR FANSAIR FLOW: HIGHEXTERNAL STATIC PRESSURE (Pa) 120 150 180 210 240 270 300 330 360 390 420 450 510 570Air flow l/s 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666Fan RPM rpm 824 844 865 885 906 926 946 965 985 1004 1024 1043 1080 1117Motor shaft input power kW 8.01 8.31 8.62 8.93 9.24 9.56 9.88 10.21 10.53 10.86 11.2 11.53 11.7 12.36Sound pressure level dB 90 90 90 91 91 91 91 91 92 92 92 92 93 93F.L.I. - Single Inlet fan kW 9 9 9 9 11 11 11 11 11 11 15 15 15 15F.L.A. - Single Inlet fan A 19.0 19.0 19.0 19.0 21.0 21.0 21.0 21.0 21.0 21.0 28.5 28.5 28.5 28.5Transmission code (fan) PF 2A 280 PF 2A 250 PF 2A 315Transmission code (motor) PV 2A 177 PV 2A 250Air flow l/s 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222Fan RPM rpm 869 889 908 927 946 965 983 1002 1020 1039 1057 1075 1110 1145Motor shaft input power kW 9.79 10.11 10.44 10.77 11.11 11.45 11.79 11.87 11.96 12.3 12.63 12.97 13.66 14.36Sound pressure level dB 92 92 92 92 92 92 93 93 93 93 93 93 94 94F.L.I. - Single Inlet fan kW 11 11 11 11 15 15 15 15 15 15 15 15 15 15F.L.A. - Single Inlet fan A 21.0 21.0 21.0 21.0 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5Transmission code (fan) PF 2A 250 PF 2A 355 PF 2A 315Transmission code (motor) PV 2A 177 PV 2A 250Air flow l/s 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 - -Fan RPM rpm 905 923 942 960 979 997 1015 1033 1050 1068 1086 1103 - -Motor shaft input power kW 11 11.33 11.68 11.76 11.85 12.19 12.53 12.87 13.21 13.56 13.91 14.26 - -Sound pressure level dB 93 93 93 93 93 93 93 94 94 94 94 94 - -F.L.I. - Single Inlet fan kW 15 15 15 15 15 15 15 15 15 15 15 15 - -F.L.A. - Single Inlet fan A 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5 - -Transmission code (fan) PF 2A 355 PF 2A 315 - -Transmission code (motor) PV 2A 250 - -Air flow l/s 9722 9722 9722 9722 9722 9722 9722 9722 9722 9722 9722 9722 9722 9722Fan RPM rpm 770 791 812 833 854 875 896 917 938 959 979 1000 1041 1082Motor shaft input power kW 11 11.4 11.9 12.1 12.3 12.8 13.3 13.8 14.3 14.8 15.4 15.9 17 18.2Sound pressure level dB 90 90 90 90 91 91 91 91 92 92 92 93 93 94F.L.I. - Single Inlet fan kW 15 15 15 15 15 15 15 15 15 18.5 18.5 18.5 18.5 18.5F.L.A. - Single Inlet fan A 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5 28.5 35.0 35.0 35.0 35.0 35.0Transmission code (fan) PF 3A 355 PF 3A 315 PF 3A 300 PF 3A 280 PF 3A 300 PF 3A 280Transmission code (motor) PF 3A 190 PF 3A 180 PF 3A 200Air flow l/s 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833Fan RPM rpm 832 851 870 889 907 926 945 964 983 1001 1020 1039 1076 -Motor shaft input power kW 13.8 14.3 14.8 15.3 15.8 16.3 16.8 17.3 17.8 18.4 19 19.5 20.7 -Sound pressure level dB 92 92 92 92 93 93 93 93 94 94 94 94 95 -F.L.I. - Single Inlet fan kW 15 15 15 18.5 18.5 18.5 18.5 18.5 18.5 22 22 22 22 -F.L.A. - Single Inlet fan A 28.5 28.5 28.5 35.0 35.0 35.0 35.0 35.0 35.0 41.0 41.0 41.0 41.0 -Transmission code (fan) PF 3A 315 PF 3A 300 PF 3A 280 -Transmission code (motor) PF 3A 180 PF 3A 190 PF 3A 200 PF 3A 190 PF 3A 200 -Air flow l/s 11667 11667 11667 11667 11667 11667 11667 11667 11667 11667 11667 11667 11667 11667Fan RPM rpm 888 906 923 941 958 976 993 1010 1028 1045 1063 1080 1115 1150Motor shaft input power kW 17 17.5 18 18.5 19.1 19.6 20.1 20.7 21.3 21.8 22.4 23 24.2 25.5Sound pressure level dB 94 94 94 94 94 94 95 95 95 95 95 95 96 96F.L.I. - Single Inlet fan kW 18.5 18.5 18.5 22 22 22 22 22 22 22 30 30 30 30F.L.A. - Single Inlet fan A 35.0 35.0 35.0 41.0 41.0 41.0 41.0 41.0 41.0 41.0 57.0 57.0 57.0 57.0Transmission code (fan) PF 3A 315 PF 3A 300 PF 3A 280 PF 3A 315 PF 3A 300Transmission code (motor) PF 3A 190 PF 3A 200 PF 3A 236Air flow l/s 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222Fan RPM rpm 922 939 955 972 988 1005 1022 1038 1055 1072 1088 1105 1138 1172Motor shaft input power kW 19.3 19.8 20.3 20.9 21.4 21.9 22.5 23.1 23.6 24.2 24.8 25.4 26.7 27.9Sound pressure level dB 95 95 95 95 95 95 95 96 96 96 96 96 97 97F.L.I. - Single Inlet fan kW 22 22 22 22 22 30 30 30 30 30 30 30 30 30F.L.A. - Single Inlet fan A 41.0 41.0 41.0 41.0 41.0 57.0 57.0 57.0 57.0 57.0 57.0 57.0 57.0 57.0Transmission code (fan) PF 3A 300 PF 3A 280 PF 3A 315 PF 3A 300Transmission code (motor) PF 3A 190 PF 3A 200 PF 3A 190 PF 3A 200 PF 3A 236Air flow l/s 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722Fan RPM rpm 839 855 871 887 902 918 934 950 965 981 996 1012 1042 1073Motor shaft input power kW 21.7 22.3 22.9 23.5 24.2 24.8 25.5 26.1 26.8 27.4 28.1 28.8 30.2 31.7Sound pressure level dB 94 94 94 94 94 94 95 95 95 95 95 95 96 96F.L.I. - Single Inlet fan kW 30 30 30 30 30 30 30 30 30 30 30 30 37 37F.L.A. - Single Inlet fan A 57.0 57.0 57.0 57.0 57.0 57.0 57.0 57.0 57.0 57.0 57.0 57.0 66.0 66.0Transmission code (fan) PF 5A 355 PF 5A 315Transmission code (motor) PF 5A 200 PF 5A 224Air flow l/s 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556Fan RPM rpm 865 881 896 911 926 941 956 971 986 1000 1015 1030 1059 1088Motor shaft input power kW 24.7 25.3 26 26.6 27.3 27.9 28.6 29.3 29.9 30.6 31.3 32 33.5 35Sound pressure level dB 95 95 95 95 95 95 96 96 96 96 96 96 97 97F.L.I. - Single Inlet fan kW 30 30 30 30 30 30 30 30 37 37 37 37 37 37F.L.A. - Single Inlet fan A 57.0 57.0 57.0 57.0 57.0 57.0 57.0 57.0 66.0 66.0 66.0 66.0 66.0 66.0Transmission code (fan) PF 5A 355 PF 5A 315Transmission code (motor) PF 5A 200 PF 5A 224 PF 5A 200 PF 5A 224The performance takes into account the pressure drops in the unit (pressure drops in treatment coil, standard filters, etc.).To determine the performance required of the fans, you must add to the usable static pressure desired the pressure drops of any accessories.The value of absorbed electrical power has already been corrected by a factor that takes into account the losses in transmission and a minimum tolerance on the number of revs of the fan.28

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!