13.07.2015 Views

Technische fiche - Delta-Temp

Technische fiche - Delta-Temp

Technische fiche - Delta-Temp

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

BT08L005GB-011500** 1500**1131050311 2012256520905 297 546PACKAGED362 - 904The unit is furnished standard for outdoor installation. For indoor installation, it is possible to equip the machine with flanges on the fresh air intake and on theexpulsion mouth.FUNCTIONAL CLEARANCESWhen placing the unit, it is necessary to comply with the functional spaces indicated in the dimensions.Compliance with fictional spaces is essential to:- ensure proper operation of the unit- allow maintenance technicians easy access to the equipment compartments- protect authorized operators and exposed persons.DIMENSIONAL DRAWINGDIMENSIONAL DRAWING(1)CRH-XHE 362 – 402 – 4522 32242625M24M2ES6012602179229560R16620 * 2730 * 620 *397098201878192717H1300R51250 6304421 227W1W215101112161314181927ES1500**232W4AEW3H16147Size 362 402 452Water connections on exchanger side2" GAS 2" 1 / 2 GAS 2" 1 / 2 GASWEIGHT DISTRIBUTIONConstructional configuration: recirculated/outside air mixing box (B)Size 362 402 452W1 kg 503 525 536W2 kg 446 462 471W3 kg 511 525 536W4 kg 568 588 600Shipping weight kg 2028 2100 2143Constructional configuration: free cooling version with extract/recirculated/fresh air intake box (C)Size 362 402 452W1 kg 555 573 586W2 kg 448 463 474W3 kg 512 529 541W4 kg 619 639 654Shipping weight kg 2134 2204 2255(1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT(2) ELECTRICAL PANEL(3) MICROPROCESSOR KEYBOARD(4) POWER INPUT(5) HUMIDIFIER INLET CONNECTIONS(6) CONDENSATE DISCHARGE(7) FUNCTIONAL CLEARANCES(8) WATER INLET INTEGRATING COIL Ø 1 1/2"(9) WATER OUTLET INTEGRATING COIL Ø 1 1/2"(10) RE-HEATING COIL (OPTIONAL)(11) TREATMENT COIL(12) WATER HEATING COIL (OPTIONAL)(13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL)(14) G4 AIR FILTERS(15) SUPPLY AND RETURN CENTRIFUGAL FANS (ONLY FOR C VERSION)(16) MOTORS WITH RETURN AND SUPPLY TRANSMISSION (ONLY FOR C VER-SION)(17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THEUNIT)(18) FRESH AIR SHUTTER(19) DISCHARGE DAMPER (ONLY FOR C VERSION)(20) RECIRCULATION SHUTTER (ONLY FOR C VERSION)(21) ACCESS TO FANS/MOTORS AND TRANSMISSIONS(22) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS(23) PANEL FOR EXCHANGER INSPECTION(24) PLATE EXCHANGER(25) PLATE EXCHANGER WATER INPUT(26) PLATE EXCHANGER WATER OUTPUT(27) RECOVERY COIL (ONLY FOR C VERSION) (OPTIONAL)R = AIR INTAKE FROM OUTSIDEM=OUTLET AIRAE = FRESH AIR INTAKEES = AIR EXPULSION(ONLY FOR C VERSION)(*) VIBRATION MOUNTS POSITION(**) CLEARANCE ACCESS RECOMMENDED50The presence of optional accessories may result in a substantial variation of the weights shown in the table.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!