<strong>1066</strong> Instruction Manual Section 10: HART CommunicationLIQ_MAN_<strong>1066</strong> September 2013Section 10: HART ® Communications10.1IntroductionThe <strong>1066</strong> transmitter can communicate with a HART host using HART Revision 5 or HART Revision7. The revision of HART used by the <strong>1066</strong> can be selected using the keypad/display or a HART mastersuch as AMS or the 475 Handheld Communicator. The default version of HART is Revision 5.Since some HART hosts cannot accommodate HART 7, the choice of HART Revision should bebased on the capabilities of the host, and should be chosen as a first step in configuration. If HARTRevision 7 can be used with the host, it does offer a number of advantages over Revision 5, includinglong tag name, time stamped data, and measurement status, and enhanced burst mode.When HART 5 is chosen, the Device Revision of the <strong>1066</strong> is Device Revision 1; when HART 7 is chosenthe Device Revision is Revision 2 (or greater). The Device Revision of the DD (Device Description)and install files for AMS and DeltaV used should be the same as the Device Revision of the <strong>1066</strong>.A single HART 5 (Device Revision 1) or HART 7 (Device Revision 2 or greater) DD (DeviceDescription) is used for all model codes of the <strong>1066</strong>, which include the pH/ORP, conductivity, oxygen,chlorine, and ozone transmitters. All <strong>1066</strong> transmitters have the same HART device identification,as outlined below:HART 5 Device Identification (<strong>1066</strong> Revision 1):Manufacturer Name: Rosemount <strong>Analytical</strong> Inc.Model Name: <strong>1066</strong>Manufacturer ID: 46 (0x2E)Device Type Code: 33 (0x0021)HART Protocol Revision: 5.1Device Revision: 110.210.2.1HART 7 Device Identification (<strong>1066</strong> Revision 2):Manufacturer Name: Rosemount <strong>Analytical</strong> Inc.Model Name: 56Manufacturer ID: 46 (0x2E)Device Type Code: 11809 (0x2E21)HART Protocol Revision: 7.3Device Revision: 2Physical Installation and ConfigurationHART Wiring and Output ConfigurationHART communications is superimposed on Analog Output 1 for all of the measurements andparameters of the <strong>1066</strong>.HART Communications 97

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!