Section 10: HART CommunicationSeptember 2013<strong>1066</strong> Instruction ManualLIQ_MAN_<strong>1066</strong><strong>1066</strong>C and <strong>1066</strong>T Status Bits continuedByte / Bit Meaning / Class Device Status Bits Set2 / 52 / 62 / 74 / 34 / 45 / 25 / 35 / 45 / 5Need Zero Calibration / WarningThe sensor offset is too high resulting in a negative reading. This trigger point forthis alert is dependent upon the conductivity measurement technology:<strong>1066</strong>C: (conductance - zero offset) < -2µS<strong>1066</strong>T: (conductance - zero offset) < -50µSA sensor zero calibration should be performed.Concentration Out Of Range / WarningThe measured concentration is outside the conductivity range where a valid concentrationcan be derived for the following 5 concentrations:0 to 20% NaCl0 to 12% NaOH0 to 15% HCl0 to 25% H2SO496 to 99.7% H2SO4.If there are no other fault conditions check process temperature and check thatthe actual concentration is outside the range for which curve is defined.Input Out Of Range / WarningThe input is outside the device measurement range. the range limits are:<strong>1066</strong>C (2- electrode conductivity): Conductance > 500mS<strong>1066</strong>CT (4- electrode conductivity): (Conductance > 3000mS) or (Vcond < 0mV)<strong>1066</strong>T: Conductance > 1500mS1. Check sensor wiring.2. Replace sensor.Calibration Error / WarningAn error occurred in the last calibration procedure.Check sensor and repeat the calibration procedure.Sensor Zero Error / WarningAn error occurred in the last sensor zero procedure.Check sensor and repeat sensor zero procedure.Sensor Zero In Progress / OtherA sensor zero is being or has been performed.Zero Cal In Water In Progress / OtherA zero calibration in water is being or has been performed.Meter Calibration In Progress / OtherA meter calibration is being or has been performed.Curve Fit In Progress / OtherA curve fit is being or has been performed.4 – More Status Available4 – More Status Available4 – More Status Available4 – More Status Available4 – More Status Available4 – More Status Available4 – More Status Available4 – More Status Available4 – More Status Available110 HART Communications